5-11
VL-H870U
VL-H875U
VL-H890U
VL-H860S/H/VL-H870S
VL-H890S/VL-H94E
VL-H96E/VL-H960E
VL-H860S/H/VL-H870S
VL-H890S/VL-H94E
VL-H96E/VL-H960E
Note: The data enclosed in the brackets [ ] are for the sub-channel.
1. Adjustment of filter f0
5-3-6. Adjustment of audio circuit
Measuring instrument
Oscilloscope
Mode
Playback
Input signal
—
Measuring terminal
TL605
Adjustment address
VCR ADJ 05F
Set value
—
(1) Connect the oscilloscope to TL605.
(2) Play back the stereo alignment tape (JiGWR5-9CS), and
adjust so that the waveform envelop of TL605 becomes as
smooth as possible. Before adjustment record the current
data of adjustment address 05F. Whenever the TELE. WIDE
key of adjustment remote controller is pressed, waveform
MAIN/SUB is switched. Select the point which gives the
flattest possible envelope.
3. Contrast adjustment
V
Measuring point
TL1814 (G-OUT)
Address 40
Mode
VCR AV input
Adjusting method
1) Set the data of address 47 at the address 80.
2) Input white 100% as an AV input.
3) Connect TL1804 to GND. (The 1H inversion stops.)
4) Connect 220 K
Ω
between TL802 and GND.
5) Seeing the waveform of TL1814 (G-OUT), make an adjustment between the
white peak and the sync tip.
Adjustment standard
3.35V
±
0.1V
Remarks
———————
5. B-W/B adjustment
Measuring point
TL1814 (G-OUT) TL1815(B-OUT)
Address 42
Mode
VCR AV input
Adjusting method
1) AV input: Nonsignal.
2) TL1814 (G-OUT): Oscilloscope CH1
3) TL1815 (B-OUT): Oscilloscope CH2
4) Adjust P-P of TL1815 become bigger 0.1V than TL1814.
Adjustment standard
±
0.1Vp-p
Remarks
———————
4. R-W/B adjustment
Measuring point
TL1814 (G-OUT) TL1813 (R-OUT)
Address 41
Mode
VCR AV input
Adjusting method
1) AV input: Nonsignal.
2) TL1814 (G-OUT): Oscilloscope CH1
TL1813 (R-OUT): Oscilloscope CH2
3) Adjust P-P of TL1813 becomes bigger 0.15V than TL1814.
Adjustment standard
±
0.1Vp-p
Remarks
———————
G R
1. LCD Data Setting
VCR ADJ
Address
Data
4C
7A
4D
B5
4E
96
4F
E5
50
64
51
A9
52
96
53
E5
4B
20
3B
40
(1) Before adjustment record the current data of adjustment
address 05E and 05D.
(2) Be sure to connect the voltage mater to TL608 [TL607].
(3) Play back the stereo alignment tape (JiGWR5-9CS), and
adjust so as to get an indication -7.5 dBs
±
0.5 dB.
(4) Watching alternately TL608 and TL607, repeat adjustment of
05E and 05D.
(5) If data differs significantly from the first record value, this
implies adjustment failure.
Measuring instrument
Voltage mater
Mode
Playback
Input signal
—
Measuring terminal
TL608 [TL607]
Adjustment address
VCR ADJ 05E [05D]
Set value
-7.5 dBs
±
0.5 dB
2. Playback level adjustment
5-3-7. Adjustment of LCD display circuit
Adjustment procedures and connections are the same as with the VCR section. (Refer to item 5-3-3)
2. Inverter input Voltage Setting
VCR ADJ
Address
Data
10
D9
11
3 type
BD
3.5 type
C6
12
3 type
99
3.5 type
A3
Summary of Contents for VL-H860H
Page 79: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 32 10 11 12 13 14 15 16 17 18 19 ...
Page 89: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 42 10 11 12 13 14 15 16 17 18 19 ...
Page 99: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 52 10 11 12 13 14 15 16 17 18 19 ...
Page 101: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 54 10 11 12 13 14 15 16 17 18 19 ...
Page 111: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 64 10 11 12 13 14 15 16 17 18 19 ...
Page 113: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 66 10 11 12 13 14 15 16 17 18 19 ...
Page 119: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 72 10 11 12 13 14 15 16 17 18 19 ...
Page 121: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 74 10 11 12 13 14 15 16 17 18 19 ...
Page 123: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 76 10 11 12 13 14 15 16 17 18 19 ...
Page 125: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 78 10 11 12 13 14 15 16 17 18 19 ...