UX-B20U/UX-B20C/B25C
2 – 8
SW
NO.
DATA
NO.
ITEM
Switch setting and function
Initial setting
Remarks
1
0
U/C
SW
l
A6
1
Reserved
0
2
Reserved
0
3
Disconnect the line when DIS is
received in RX mode
No
Yes
1
4
Equalizer freeze control (MODEM)
On
Off
0
5
Equalizer freeze control 7200 BPS
only
No
Yes
0
6
CNG transmission in manual TX
mode
Yes
No
1
7
Initial compression scheme for
sharp fax in TX mode
MR mode
H2 mode
0
8
Modem speed automatic fallback
when RX level is under -40dBm
Yes
No
0
SW
l
B1
1
2
3
4
Recall interval
0
1
0
1
5
6
7
8
Recall times
0
0
1
1
SW
l
B2
1
Dial pausing (sec/pause)
4 sec
2 sec
0
2
Dial tone detection (before auto dial) No
Yes
1
3
Reserved
0
4
Busy tone detection (after auto dial)
No
Yes
0
5
6
Waiting time after dialing
45 sec
55 sec
90 sec
140 sec
0
0
No. 5
0
0
1
1
No. 6
0
1
0
1
7
Reserved
0
8
Reserved
0
SW
l
B3
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
7
Auto dial mode delay timer of before
line connect
0 sec
1.5 sec
3.0 sec
4.5 sec
0
0
No. 6
0
0
1
1
No. 7
0
1
0
1
8
Hold key
Enable
Disable
1
SW
l
B4
1
2
Auto dial mode delay timer of after
line connect
1.7 sec
3.0 sec
3.6 sec
4.0 sec
0
0
No. 1
0
0
1
1
No. 2
0
1
0
1
3
Dial mode
Tone
Pulse
1
OPTION
4
Pulse
→
Tone change function by
key
Enable
Disable
1
5
Dial pulse make/break ratio (%)
40/60
33/67
1
6
Reserved
0
7
Reserved
0
8
Recalling fixed only one time when
dialing was unsuccessful without
detecting busy tone signal
Yes
No
1
Binary input
No. = 8 4 2 1
1 2 3 4
EX 0 1 0 1
eg. Recall interval is set to 5 min.
Binary input
No. = 8 4 2 1
5 6 7 8
EX 0 0 1 1
eg. Recall time is set to 3 times.