8
SJ-21P
SJ-D25P
WIRING DIAGRAM
Be sure to replace the electrical parts with specified ones for maintaining the safety and performance of the set.
Figure W-1. Wiring Diagram
CONNECTOR
CONNECTED IN
TERMINAL BOX
Compressor
Starting relay
(P.T.C relay)
(Bk)
C
M
A
(Br)
Lamp
(S-B)
(Br)
(G)
(R)
Protector
(Overload relay)
(B)
(B)
(O)
(Y)
(Y)
(O)
(Bk)
2
3
4
1
(W)
Door
Switch
Fan Motor
Defrost
Heater
Compartment
Heater
Defrost
Thermo.
Thermo.
Fuse
R-Thermo.
Compensating
Thermo.
2PIN AC
Plug /
Cord
Defrost
Timer
B : BLUE
G : GRAY
Bk : BLACK
P : PINK
Br : BROWN
S-B : SKY-BLUE
O: ORANGE
W: WHITE
Y: YELLOW
R: RED
FM
TM
L
LIST OF ELECTRICAL PARTS
ITEMS
TYPE NAME
RATING
SPECIFICATIONS
Defrost thermostat
S101
125V,15A
Open : 10˚C , Close : 1˚C
Timer
TMDFX04FB2
100-127V
Integration type
50/ 60Hz
Cycle time : 10h (60Hz)
Delay time : 4m (60Hz)
Thermo. fuse (defrost) SF70E
250V,10A
Cut off temperature : 70˚C
Door switch
100424NC
250V,0.25A
2 terminals type push-button
Fan motor
3R00057B
110V,60Hz
—
Lamp
—
110V,10W
E-12
Lamp socket
—
250V,1A
E-12 (Hard plastic body type)
R-thermostat
MM1-8071F
—
ON : 3.5˚C , OFF : 0.5˚C
Defrost heater
—
100-110V
78.8
Ω
without deodorizer (SJ-21P)
78.8
Ω
with deodorizer (SJ-D25P)
Compressor
EMI50HNP
115V
Main : 3.85
Ω
60Hz
Aux : 7.70
Ω
Cooling capacity 151W
Terminal shape
1
Starting relay
P600E
—
—
Protector
4TM319RFBYY
—
—
Compensating thermostat
S101
125V,15A
Open : 25˚C , Close : 17˚C
Compartment heater
—
110V, 4.8W
2500
Ω
The black dot ( ) indicates non-replacement parts or part which is not replaceable itself.
Common
Main coil