O
PROCEDURES TO BE TAKEN WHEN THE FOIL PATTERN ON THE PRINTED WIRING
BOARD (PWB) IS OPEN
To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary
on the PWB, this foil pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide
given below for repair.
Problem: POWER ON, indicator does not light up.
CARRY OUT 3D CHECKS.
STEPS
OCCURRENCE
CAUSE OR CORRECTION
1
The rated AC voltage is not present at
Check supply voltage and oven power cord.
POWER terminal of CPU connector (CN-A).
2
The rated AC voltage is present at primary
Low voltage transformer or secondary circuit defective.
side of low voltage transformer.
Check and repair.
3
Only pattern at "a" is broken.
*Insert jumper wire J1 and solder.
(CARRY OUT 3D CHECKS BEFORE REPAIR)
4
Pattern at "a" and "b" are broken.
*Insert the coil RCILF2003YAZZ between "c" and "d".
(CARRY OUT 3D CHECKS BEFORE REPAIR)
NOTE: *At the time of these repairs, make a
visual inspection of the varistor for burn-
ing damage and examine the transformer
with tester for the presence of layer short-
circuit (check primary coil resistance). If
any abnormal condition is detected, re-
place the defective parts.
CARRY OUT 4R CHECKS.
RY2
OL / FM
/ TTM
AC
5
1
D20
VRS1
a
b
d
c
CN - A
D21
RY1
(J1)
T1
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
R64ST_S.MANUAL
12/8/01, 11:01 am
20