3
INSTALLATION INSTRUCTIONS
1. Remove all packing materials from the oven cavity, (do not remove the waveguide cover), and the feature
sticker from the outside of the door, if there is one. Check the unit for any damage, such as a misaligned door,
damaged door seals around the door or dents inside the oven cavity or on the door. If there is any damage,
please do not operate the oven until it has been checked by a SERVICE CENTRE APPROVED BY SHARP
and repaired, if necessary.
2. Accessories provided
1) Turntable
2) Roller stay
3) Operation manual and Cooking guides
3. Place the roller stay in the coupling on the oven floor, then place the turntable on to the roller stay, ensuring
it is located firmly. Refer to OVEN DIAGRAM on page 4. NEVER operate the oven without the roller stay and
turntable.
4. This oven is designed to be used on a countertop only. It should not be installed in any area where excessive
heat and steam are generated, for example, next to a conventional oven unit.
The oven should be installed so as not to block ventilation openings.
Allow at least 15 cm on the top of the oven for adequate air circulation. This oven is not designed to be built-
in to a wall or cabinet.
5. Neither the manufacturer nor the distributors can accept any liability for damage to the machine or personal
injury for failure to observe the correct electrical connecting procedure. The A.C. voltage and frequency must
be single phase 230-240V, 50Hz.
6.
WARNING-THIS APPLIANCE MUST BE EARTHED.
If the socket outlet in your house is not compatible with the plug supplied, cut-off the mains plug and fit an
appropriate type, observing the wiring cord below.
If you are unsure how to do this get help from an electrician.
IMPORTANT - The wires in power supply cord are coloured in accordance with the following code:
Green-and-yellow
:
Earth
Blue
:
Neutral
Brown
:
Live
As the colours of the wires in the power supply cord of this appliance may not correspond with the coloured
marking identifying the terminals in your plug, proceed as follows:
The wire which is coloured green-and-yellow must be connected to the terminal in the plug which is marked
with the letter E or by the earth symbol or coloured green or green-and-yellow.
The wire which is coloured blue must be connected to the terminal which is marked with the letter N or
coloured blue.
The wire which is coloured brown must be connected to the terminal which is marked with the letter L or
coloured brown.
NOTE:
Under no circumstances should the cut-off plug be inserted into a socket outlet as a serious electric
shock may occur.
R260L EN P01-04
06.12.8, 3:31 PM
3