R-25JT-F
4
ITEM
DESCRIPTION
Power Requirements
230/208 Volts 3.2 kW
Approx. 15.5 A at 208 V / Approx. 14.5 A at 230 V
60 Hertz / Single phase, 3 wire grounded
Power Output
2100 watts (IEC 705 Test Procedure) Operating frequency of 2450MHz
Case Dimensions
Width 20-1/8" (510mm) Height 13-1/4" (335mm) Depth 18-1/2" (470mm)
Cooking Cavity Dimensions
Width 13" (330mm)
Height 7-1/8" (180mm) Depth 13" (330mm)
Control Complement
Touch Control System
Digital Display
10 Number Pads
STOP/CLEAR pad
START pad
SELECTAPOWER pad (Power level: 0 to 100%)
SELECTATIME pad
DOUBLE QUANTITY pad
EXPRESS DEFROST pad
Memory SET pad
Memory CHECK pad
SIGNAL pad
Weight
Approx. 68 lbs/ 31 kg
Safety Standard
UL Listed FCC Authorized
DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J
NSF Certified
SPECIFICATION
GENERAL INFORMATION
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing
an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The
plug must be plugged into an outlet that is properly installed and grounded.
WARNING: Improper use of the grounding plug can result in a risk of electric shock. The electrical requirements are 230/208 Volt,
60 Hz, AC only, and 20 Amp or more fused electrical supply. It is recommended that a separate circuit serving only
this appliance be provided. When installing this appliance, observe all applicable
codes and ordinances. If it is necessary to use an extension cord, use only a 3-wire
extension cord that has a 3-blade grounding plug and a 3-slot receptacle that will
accept the plug on the appliance. The marked rating of the extension cord should
be AC 230/208 Volt 20 Amp.
VOLTAGE SELECT
The oven has been preset for 230V operation.
If you need to change this oven for 208V operation, follow instructions below.
1. Unplug oven.
2. Remove one screw(A) from the Voltage Select Cover located on back of the oven
near the bottom.
3. Remove the Voltage Select Cover and rotate 180 degrees.
4. Reinstall the Voltage Select Cover using one screw(A) removed in Step 2.
5. Plug power cord into wall outlet.
Your oven is now ready for 208V, 60Hz operation.
Note: If “EE4” or “EE5” appears in the lighted digital display, a voltage adjustment
must be made.
Receptacle Box Cover
3-Pronged plug
(6-20P)
3-Pronged, Receptacle
(6-20R)
Power supply
cord
230 V
230 V
208 V
208 V
(A)