CHARGED SECTION AND HIGH VOLTAGE GENERATING POINT
Ë
Charged Section
The places where the commercial AC power is used without
passing through the power supply transformer.
If the places are touched, there is a risk of electric shock. In
addition, the measuring equipment can be damaged if it is
connected to the GND of the charged section and the GND of
the non-charged section while connecting the set directly to
the commercial AC power supply. Therefore, be sure to
connect the set via an insulated transformer and supply the
current.
1. AC Power Cord
2. AC Inlet with Filter
3. Power Switch (S1)
4. Fuse (In the SW POWER SUPPLY Module)
5. STB Transformer and Converter Transformer
(In the SW POWER SUPPLY Module)
6. Other primary side of the SW POWER SUPPLY Module
Ë
High Voltage Generating Point
The places where voltage is 100V or more except for the
charged places described above. If the places are touched,
there is a risk of electric shock.
1. SW POWER SUPPLY Module .............................. (225V)
2. X DRIVE Assy ....................................... (–300V to 225V)
3. Y DRIVE Assy ....................................................... (355V)
4. SCAN (A) Assy ...................................................... (355V)
5. SCAN (B) Assy ...................................................... (355V)
6. X CONNECTOR (A) Assy ..................... (–300V to 225V)
7. X CONNECTOR (B) Assy ..................... (–300V to 225V)
AC Inlet with Filter
Power Cord
Power Switch
(S1)
Fig.1 Charged Section and High Voltage Generating Point (Rear View)
: Part is the High Voltage Generating Points
other than the Charged Section.
: Part is Charged Section.
X DRIVE
Assy
X CONNECTOR (B)
Assy
Y DRIVE
Assy
SCAN (A)
Assy
SCAN (B)
Assy
∗
Remove the IF Earth Metal beforehand when inclines
the power supply unit as the right figure.
X CONNECTOR (A)
Assy
SW POWER SUPPLY
Module
Top
Front
Summary of Contents for PZ-50HV2
Page 11: ...11 PZ 50HV2 PZ 50HV2E PZ 50HV2U DIMENSIONS Unit mm ...
Page 116: ...159 A B C D 5 6 7 5 6 7 8 PZ 50HV2 PZ 50HV2E PZ 50HV2U 158 A B C D 2 3 4 1 2 3 4 ...
Page 122: ...A B C D 2 3 4 1 2 3 4 PZ 50HV2 PZ 50HV2E PZ 50HV2U 170 Ë SP TERMINAL ASSY ...
Page 123: ...PZ 50HV2 PZ 50HV2E PZ 50HV2U 171 ...
Page 141: ...A B C D 2 3 4 1 2 3 4 200 Ë MR INTERFACE ASSY MR INTERFACE ASSY ANP1997 B SIDE A ...
Page 142: ...A B C D 1 2 3 1 2 3 4 PZ 50HV2 PZ 50HV2E PZ 50HV2U 201 MR INTERFACE ASSY ANP1997 B SIDE B ...
Page 195: ...254 PZ 50HV2 PZ 50HV2E PZ 50HV2U PACKING OF THE SET F 1 2 11 12 3 7 10 7 8 5 9 7 2 6 4 13 8 ...