Input Signal
Adjusting Point
Adjusting Method
White 100%
REF_DIG mode
in Factory mode
XSUSB ADJ
YSUSB ADJ
X-SUS-B, Y-SUS-B Adjustment
Set to the indicated value with the remote control unit.
(Refer to "Timing adjustment of control signal of X and Y Drive Assys".)
Input Signal
Adjusting Point
Adjusting Method
White 100%
VR3701 (VRN)
(X DRIVE Assy)
VRN (minus reset voltage adjustment)
Adjust so that the voltage between K3707 (VRN) and K3702 (SUS-GND) becomes
-300V
±
1.0V.
Input Signal
Adjusting Point
Adjusting Method
Reference : Adjustment values using the Media color-difference meter (CA-100)
Adjust the parameter in the OFFSET-DIGITAL of factory mode as follows;
PANEL R-HIGH
PANEL B-LOW
In this time, dispay uses the mask (MASK04) of factory mode.
Sustain Pulse Waveform Adjustment
VRN Voltage Adjustment
Panel White Balance Adjustment
MASK Left Side
x
295
y
306
MASK Right Side
291
300
∗
When perform the various adjustment by RS-232C control, execute a "DM0" command (release the limit of pulse number)
beforehand.
After the adjustment completion, execute a "DM 3" command (Limit of pulse number: 64%, shipping state) by all means.
Summary of Contents for PZ-50HV2
Page 11: ...11 PZ 50HV2 PZ 50HV2E PZ 50HV2U DIMENSIONS Unit mm ...
Page 116: ...159 A B C D 5 6 7 5 6 7 8 PZ 50HV2 PZ 50HV2E PZ 50HV2U 158 A B C D 2 3 4 1 2 3 4 ...
Page 122: ...A B C D 2 3 4 1 2 3 4 PZ 50HV2 PZ 50HV2E PZ 50HV2U 170 Ë SP TERMINAL ASSY ...
Page 123: ...PZ 50HV2 PZ 50HV2E PZ 50HV2U 171 ...
Page 141: ...A B C D 2 3 4 1 2 3 4 200 Ë MR INTERFACE ASSY MR INTERFACE ASSY ANP1997 B SIDE A ...
Page 142: ...A B C D 1 2 3 1 2 3 4 PZ 50HV2 PZ 50HV2E PZ 50HV2U 201 MR INTERFACE ASSY ANP1997 B SIDE B ...
Page 195: ...254 PZ 50HV2 PZ 50HV2E PZ 50HV2U PACKING OF THE SET F 1 2 11 12 3 7 10 7 8 5 9 7 2 6 4 13 8 ...