Command
Function
GAJ
Output data of an electronic VR adjustment value and a drive system adjustment value
GPW
Output data to be related to white balance adjustment of the panel
GS1
Output data such as version information, hour meter and pulse meter
Order
Data Contents
Size
Remarks
1
Setting mode of electric power upper limit value
3 byte
AB* ( *: 0 to 3)
2
Electric power upper limit value
(ABL)
(Reference data)
3 byte
3
(Offset data)
3 byte
(Note 1)
4
Vsus adjustment value
(Reference data)
3 byte
5
Vofs adjustment value
(Reference data)
3 byte
6
V-SUS-B adjustment value
(Reference data)
3 byte
7
V-SUS-G adjustment value
(Reference data)
3 byte
8
Y-SUS-B adjustment value
(Reference data)
3 byte
9
Y-SUS-G adjustment value
(Reference data)
3 byte
Order
Data Contents
Size
Remarks
1
Panel color temperature mode
3 byte
PT* ( *: 0 to 3)
2
Gain of W/B adjustment value
Red
(Reference data)
3 byte
3
(Offset data)
3 byte
(Note 1)
4
Gain of W/B adjustment value
Green
(Reference data)
3 byte
5
(Offset data)
3 byte
(Note 1)
6
Gain of W/B adjustment value
Blue
(Reference data)
3 byte
7
(Offset data)
3 byte
(Note 1)
8
Offset of W/B adjustment value
Red
(Reference data)
3 byte
9
(Offset data)
3 byte
(Note 1)
10
Offset of W/B adjustment value
Green
(Reference data)
3 byte
11
(Offset data)
3 byte
(Note 1)
12
Offset of W/B adjustment value
Blue
(Reference data)
3 byte
13
(Offset data)
3 byte
(Note 1)
GAJ:
Output data of an electron VR adjustment value and a drive system adjustment value
• Output it according to transmission order and size of the table below.
GPW
(Get Panel White balance)
:
Output data to be related to white balance adjustment of panel
• Output it according to transmission order and size of the table below.
(Note 1) : When performed in reference mode selection, offset data outputs the same value as the reference data.
(Note 2) : Checksum of 2 bytes is added at the end, but ignore it.
(Note 1) : When performed in reference mode selection, offset data outputs the same value as the reference data.
(Note 2) : Checksum of 2 bytes is added at the end, but ignore it.
Command Description
GET Command
Summary of Contents for PZ-50HV2
Page 11: ...11 PZ 50HV2 PZ 50HV2E PZ 50HV2U DIMENSIONS Unit mm ...
Page 116: ...159 A B C D 5 6 7 5 6 7 8 PZ 50HV2 PZ 50HV2E PZ 50HV2U 158 A B C D 2 3 4 1 2 3 4 ...
Page 122: ...A B C D 2 3 4 1 2 3 4 PZ 50HV2 PZ 50HV2E PZ 50HV2U 170 Ë SP TERMINAL ASSY ...
Page 123: ...PZ 50HV2 PZ 50HV2E PZ 50HV2U 171 ...
Page 141: ...A B C D 2 3 4 1 2 3 4 200 Ë MR INTERFACE ASSY MR INTERFACE ASSY ANP1997 B SIDE A ...
Page 142: ...A B C D 1 2 3 1 2 3 4 PZ 50HV2 PZ 50HV2E PZ 50HV2U 201 MR INTERFACE ASSY ANP1997 B SIDE B ...
Page 195: ...254 PZ 50HV2 PZ 50HV2E PZ 50HV2U PACKING OF THE SET F 1 2 11 12 3 7 10 7 8 5 9 7 2 6 4 13 8 ...