Copyright
©
All rights reserved, SHARP CORPORATION
Confidential
55
Factory calibration data has been stored in the display.
The visibility of color unevenness between displays may be increased by temperature differences between
in the factory and in the installation location and by the degradation depending on the purpose of use.
Measure color again and re-adjust with DITwC
*1
to achieve color consistency across the whole video wall.
4.6.Calibration with measuring devices(5)
Measuring devices
Recommended models
1. Contact type
・
Datacolor Spyder3Pro
*2
/Spyder4Pro/Spyder5Pro
・
X-rite ColorMunki Photo/ Design
*2 Not compatible with Windows 8/8.1/10.
2. Non-contact type
*3
・
FLIR Integrated Imaging Solutions, Inc Blackfly GigE/PoE (BFLY-PGE-
05S2C-CS)
*3 When measuring and adjusting one display, use the contact type, not the non-contact one.
USB
LAN cable
*4
A measuring device
1. Contact type
A measuring device
LAN
Adjustment PC
Adjustment PC
2. Non contact type
Measure each display separately.
The whole video wall
can be measured at a
time.
*1 DITwC
…Display Installation Tool with Calibration Utility
*4 Can connect via also RS-232C
Refer to DITwC manual for further information.
Summary of Contents for PN-V701
Page 3: ...Copyright All rights reserved SHARP CORPORATION Confidential 2 1 Overall precautions ...
Page 8: ...Copyright All rights reserved SHARP CORPORATION Confidential 7 2 Design precautions ...
Page 26: ...Copyright All rights reserved SHARP CORPORATION Confidential 25 3 Installation precautions ...
Page 50: ...Copyright All rights reserved SHARP CORPORATION Confidential 49 4 Color adjustment ...
Page 76: ......