43
E
Controlling the Monitor with a PC (RS-232C)
Function
Command Direction
Parameter
Reply
Control/Response contents
*
ID SETTING
ID No. SET
IDST
W
0-255
Sets the monitor’s ID number. (“0” means “no ID number”.)
○
R
0-255 Returns the monitor’s ID number.
ID NO. SETTING
(ONCE)
IDSL
W
1-255
Set a monitor’s ID number to send a command.
This ID number is only effective for the command immediately after this command.
0
Clears the ID number if one has been designated.
ID NO. SETTING
(SUBSEQUENT)
IDLK
W
1-255
Set a monitor’s ID number to send a command.
This ID number is effective for the next and all subsequent commands after this
command.
0
Clears the ID number if one has been designated.
ID CHECK
IDCK
W
0 ID
: xxx
IDLK : yyy
Displays monitor’s own ID number and the selected ID number on the screen.
ID DISPLAY
IDDP
W
0-2
0: OFF, 1: ON, 2: ON (turns OFF after 4 sec.)
(The IP address and MAC address are both displayed.)
-
REMOTE No.
RCNO
WR
0-9
0-9 Sets the number of the remote control.
○
COPY SETTING
VALUE
COPY TO ID No.
CPMD
WR
0
0 Copy to all monitors.
1-255
1-255 Copy to the monitor with the set ID number.
COPY SETTING
VALUE TARGET
CPTG
WR
0
0 Copies the PICTURE menu settings.
1
1 Copies all the settings.
SUPPLY USB POWER
PWSP
WR
0-1
0-1 0: POWER ON ONLY, 1: ALWAYS
-
MONITOR menu
Function
Command Direction
Parameter
Reply
Control/Response contents
*
PORTRAIT/LANDSCAPE INSTALL
STDR
WR
0-1
0-1 0: LANDSCAPE, 1: PORTRAIT
○
HORIZONTAL INSTALLATION
MLAY
WR
0-2
0-2 0: OFF, 1: UPWARD, 2: DOWNWARD
ROTATE 180°
PFIL
WR
0, 3
0, 3 0: OFF, 3: ON
“ERR” when PIP MODES is a value other than OFF.
OSD H-POSITION
OSDH
WR
0-100
0-100 “ERR” when PORTRAIT/LANDSCAPE INSTALL is set to PORTRAIT.
OSD V-POSITION
OSDV
WR
0-100
0-100
OPERATION MODE
FNCM
WR
0-1
0-1 0: MODE1, 1: MODE2
POWER SAVE MODE
STBM
WR
0-1
0-1 0: OFF, 1: ON
“ERR” when SUPPLY USB POWER is set to ALWAYS.
OFF IF NO
OPERATION
SET
ATOF
WR
0-1
0-1 0: OFF, 1: ON
TIME
AOFT
WR
1-12
1-12 1-12: 1-12 hours
POWER ON DELAY
SET
PODS
WR
0-1
0-1 0: OFF, 1: ON
INTERVAL
PWOD
WR
1-60
1-60 1-60: 1-60 seconds
SELF ADJUST
SELF ADJUST
AADJ
WR
0-1
0-1 0: OFF, 1: ON
START TIMING
AADD
WR
10-200
10-200 10: 1 second through 200: 20 seconds