40
E
RS-232C command table
How to read the command table
Command:
Command field (See page 38.)
Direction:
W When the “Parameter” is set in the parameter field (see page 38), the command functions as described
under “Control/Response Contents”.
R The returned value indicated under “Reply” can be obtained by setting “????” or “
?” in the
parameter field. (See page 38.)
Parameter:
Parameter field (See page 38.)
Reply:
Response (Returned value)
TIPS
• In the standby mode, the only command that is used is Power control.
Power control/Input mode selection
Function
Command Direction
Parameter
Reply
Control/Response contents
Power control
POWR
W
0
Switches to standby mode.
1
Returns from standby mode.*
R
0 Standby mode
1 Normal mode
Input mode selection
INPS
W
0
Toggle change for input mode.
2
VGA
3
YPBPR
4
AV
10
HDMI 1
13
HDMI 2
18
HDMI 3
21
OPS
“ERR” when nothing is attached in the expansion slot.
24
APPLICATION
R
2 VGA
3 YPBPR
4 AV
10 HDMI 1
13 HDMI 2
18 HDMI 3
21 OPS
24 APPLICATION
* You can use “Wake On LAN (Magic Packet)” to turn on the power via LAN.
It is not possible to turn on the monitor with the IP Control command.
Picture menu
Function
Command Direction
Parameter
Reply
Control/Response contents
BRIGHT
VLMP
WR
0-100
0-100
SIZE (Screen size selection)
WIDE
W
0
0 Toggle change for screen size.
WR
1-5
1-5 1: 16:9, 2: Dot by Dot, 3: 4:3, 4: Zoom1, 5: Zoom2
Sound menu
Function
Command Direction
Parameter
Reply
Control/Response contents
VOLUME
VOLM
WR
0-100
0-100
MUTE AUDIO
MUTE
WR
0-1
0-1 0: OFF, 1: ON