Additional Item(s) Excluded from Warranty Coverage

Warranty coverage does not apply when:

  a)  The product is installed or repaired or serviced  in a manner that is contrary to Sharp’s Installation Manual;
  b)  The product is installed in a mobile or marine environment, 
  c)  The product is subjected to improper voltage or power surges or abnormal environmental conditions (such as acid rain or other pollution);
  d)  The components in the construction base on which the module is mounted are defective; 
  e)  External corrosion, mold discoloration or the like occurs;
  f)  The product has been moved from its original installation;
  g)  The model number or serial number of the product is altered, removed or rendered illegible. 
Sharp’s aggregate liability in connection with the Product, if any, shall not exceed the purchase price paid to Sharp for the Product or service which 
gave rise to the claim under the Limited Warranty. 

The repair, replacement of the Product, or the supply of additional Product does not cause the beginning of new warranty terms, nor shall the original 
warranty terms of this Limited Warranty be extended. Any replaced product shall become Sharp’s property

Where to Obtain Service:

Warranty service is available at a Sharp Authorized Service Center Dealer located in the United States. To find 
the location of the nearest Sharp Authorized Service Center Dealer, call Sharp toll free at 1-800 SOLAR06 (800-
765-2706). 
Call toll free at 1-800-765-2706 to obtain a Return Authorization Number and shipping instructions. Proof of 
Purchase will be required. 

What to do to Obtain Service:

Ship prepaid your Product to a Sharp Authorized Service   Center Dealer. Be sure to have Proof of Purchase 
available. If you ship the Product, be sure it is insured and packaged securely. Sharp will not be responsible for 
damage incurred during transport.

Summary of Contents for NU-Q240F2

Page 1: ...ect PV modules directly to motor loads Variation in PV module output power as a function of solar irradiance may damage directly connected loads For example 1 In the case of a brushless motor the lock function may become active and the motor may be damaged 2 In the case of a brush type motor the coil may be damaged GENERAL SAFETY 1 Wiring and grounding method of the frame of arrays shall comply wi...

Page 2: ...g or in a raceway to prevent movement of the interconnect cable over time Cable support should be done in a way to avoid the connector from scratching or impacting the back sheet of the module 11 Do not touch the terminal box and the end of the interconnect cables connectors with bare hands during installation or under sunlight regardless of whether the PV module is connected to or disconnected fr...

Page 3: ...e Figure 3 1954381 2 The grounding clip SolKlip grounding Clip Assemblies 1954381 2 Tyco electronics corp E69905 assembly consists of a slider base and 8 32 screw and hex nut screw and hex nut are parts in component of 1954381 2 1 Place the grounding onto the frame making sure that the screw straddles the grounding hole 2 Thread the hex nut onto the end of the screw tighten the nut Recommended tor...

Page 4: ...surface Mounting Using Frame Bolt Holes Figures 6 7 The modules may be fastened to a support using the bolt holes in the bottom of the frame at location C as shown in Figure 7 back view of the module and Figure 6 mounting detail The module should be fastened with four 4 M8 5 16 bolts Recommended torque value is 12 5 Nm For your reference please use the washer specified as below for the minimum req...

Page 5: ...required dimensions Clamp Thickness Minimum mm Clamp Width Minimum mm Catch Width Minimum mm Support Width Minimum mm Option A 3 3 mm 38 mm 5 mm 10 mm Option B 3 0 mm 43 6 mm 5 mm 10 mm C C C C Figure 6 Figure 7 5 9 150 mm e 16 1 410 mm 5 9 150 mm s 16 1 410 mm Figure 8 Figure 9 ...

Page 6: ... H240Q2 ND Q240Q2 ND H235Q2 ND Q235Q2 ND H230Q2 ND Q230Q2 Maximum Power Pmax 245 0 W 240 0 W 235 0 W 230 0 W Open Circuit Voltage Voc 37 6 V 37 5 V 37 2 V 37 1 V Short Circuit Current Isc 8 63 A 8 61 A 8 59 A 8 48 A Voltage at maximum power Vpmax 30 4 V 30 2 V 30 1 V 30 0 V Current at maximum power Ipmax 8 06 A 7 95 A 7 81 A 7 67 A Maximum System Voltage 600 V 600 V 600 V 600 V Minimum Blocking di...

Page 7: ...output This warranty is transferable when product remains installed in original location at the time of product warranty registration This warranty does not apply to any alteration of the appearance of the Product that does not affect the performance or functionality of the Product nor to the additional excluded item s set forth below nor to any Product in Sharp s sole discretion the exterior of w...

Page 8: ...ction with the Product if any shall not exceed the purchase price paid to Sharp for the Product or service which gave rise to the claim under the Limited Warranty The repair replacement of the Product or the supply of additional Product does not cause the beginning of new warranty terms nor shall the original warranty terms of this Limited Warranty be extended Any replaced product shall become Sha...

Reviews: