36
XG-C58X
XG-C68X
No
Other
No
Yes
No
Yes
BU5.3V
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Checking the power unit
There is no voltage output at
P804
Which output voltage line fails?
Is AC voltage(108~264V)applied
across the P701 connector?
Is AC voltage(108~264V)applied
across the P801 connector?
Is the fuse F701 open?
Is the resistor R717 open?
Is the Bimetal SW open
Replace Inlet unit.
Check the Output PWB unit
Check the T804, IC802, IC804,
and their peripheral circuits.
Check the P701 or AC cord.
Is the resistor R809 open?
Replace Power unit.
Replace the R809.
Replace the F701.
Replace the R717.
Push the red button of the bimetal.