![Sharp MX-M265N Service Manual Download Page 195](http://html.mh-extra.com/html/sharp/mx-m265n/mx-m265n_service-manual_365744195.webp)
MX-M316N MAINTENANCE 9 – 4
2. Other related items
A. Counter clear
*: When maintenance message is displayed, replace consumption part reaching the number of sheets of maintenance, then clear the replaced
part's counter only.
3. Display of maintenance execution timing
The message of maintenance execution timing is displayed when each counter reaches the set value. The relations between the messages
and the counters are shown below.
A. Maintenance counter
* After execution of maintenance, be sure to execute SIM24-4 to clear the maintenance counter (Total).
B. Transfer unit
* After execution of the maintenance, execute SIM24-4 to clear the transfer unit print counter, the accumulated number of rotations counter
and the use day counter.
C. Fusing unit
* After execution of the maintenance, execute SIM24-4 to clear the fusing heat roller print counter, the accumulated rotation number counter
and the use day counter.
D. OPC drum
* Judgment is made at the earlier timing of the drum print counter or the drum rotations accumulated number counter.
E. Developer
* Judgment is made at the earlier timing of the developer print counter or the developer accumulated rotation number counter.
The developer rotation number is synchronized with the drum motor rotation number.
Item
SIM
Remarks
Maintenance cycle setting
SIM 21-1
Jam/trouble counter clear
SIM 24-1
Paper feed counter clear
SIM 24-2
Scan/Stapler/Stamp counter clear
SIM 24-3
Maintenance counter clear
SIM 24-4
*
Copy counter clear
SIM 24-6
Printer/other counter clear
SIM 24-9
FAX counter clear
SIM 24-10
Scanner mode counter clear
SIM 24-15
Display content
Display condition
Print JOB Enable/
Disable
SIM26-38-A
set value
Counter name
Counter value
-
0 (Print continue)
Maintenance counter (Total)
When 90% of the SIM21-1 set
value is reached.
-
Maintenance required. Code: TA
1 (Print stop)
Enable
Maintenance required. Code: TA
0 (Print continue)
When the SIM21-1 set value is
reached.
Enable
1 (Print stop)
Disable
Display content
Display condition
Print JOB Enable/
Disable
Counter name
Counter value
Maintenance required.: TK
Transfer unit print counter
150K
Enable
Display content
Display condition
Print JOB Enable/
Disable
Counter name
Counter value
Maintenance required.: FK1
Fusing heat roller print counter
150K
Enable
Maintenance required.: FK2
Pressure roller print counter
300K
Display content
Display condition
Print JOB Enable/
Disable
Counter name
Counter value
Maintenance required.: DK
OPC drum print counter
100K
Enable
Maintenance required.: DK
OPC drum accumulated rotation number counter
550K rotations
Display content
Display condition
Print JOB
Enable/Disable
Counter name
Counter value
Maintenance required.: VK
Developer print counter
100K
Enable
Maintenance required.: VK
Developer accumulated rotation number counter
550K rotations