MX-M264U Dehumidifying heater kit 23 – 4
(2) Table glass removal
1)
Remove the glass holder. Remove the table glass and the
SPF glass.
(3) Scanner heater unit attachment
1)
Attach the clamp to the scanner frame.
NOTE:
When installing, be careful to prevent damage of the
wire.
2)
Remove two screws from the scanner bottom.
3)
Connect the harness of the scanner heater. Attach the scanner
heater unit, and fixing the screw (M3 x 4 Round-tipped).
4)
Attach the scanner heater and secure it with the screw (M4 x 6
Bind machine screw). Pass the harness through the clamp.
NOTE:
The convex part of the scanner heater must be
inserted into the hole of the scanner frame.
5)
Tighten the loose scanner heater harness by pulling it in the
arrow direction and secure it with the snap band then cut its tip
to approx. 5 mm or less.
6)
Move the lamp unit by hand and check that it move smoothly in
all movable area.
NOTE:
Check that there is no interference of the harness of
the scanner heater in the wire and the 2/3 mirror unit.
1
4
5
2
3
2
2
1
1
2