MX-M1204 MX-M904/M1054/M1204 (MAIN UNIT) 2 – 13
G. Toner collection container check
1)
Open the front cover (a).
2)
Check to confirm that toner collection container (a) is securely
installed.
H. Toner density reference control level setting
1)
Connect the power cord of the main unit to the power
outlet.
2)
Open the front cover, and turn ON the main power switch.
3)
Turn ON the power switch on the operation panel.
4)
Open the front cover, and remove the toner cartridge. Then
enter the input of SIM25-2.
5)
After entering the simulation, close the front cover (a).
6)
Press [EXECUTE] button, and the simulation is executed.
After stirring toner, the toner density control sensor values are
sampled to get the average value of the sensor detection level,
which is set (saved) as the reference toner density control
value.
7)
After completion of the reference toner density control value
setting, [EXECUTE] key returns to the normal display, showing
completion of the setting operation.
I.
Toner cartridge installation
1)
Pull out the toner tray (a).
b
a
a
a
a
a