MX-C250 SIMULATION 6 – 70
9
1-4
Setting
External line connection number
setting 1 <Second digit>
The numbers and codes which
can be registered are as fol-
lows.
0 - 9 / * (a) / # (b) / – (pause)
(c) / Not used for this digit and
after (d) /
Any is OK (f).
5-8
Setting
External line connection number
setting 1 <Third digit>
The numbers and codes which
can be registered are as fol-
lows.
0 - 9 / * (a) / # (b) / – (pause)
(c) / Not used for this digit and
after (d) /
Any is OK (f).
10
1-4
Setting
External line connection number
setting 1 <Fourth digit>
The numbers and codes which
can be registered are as fol-
lows.
0 - 9 / * (a) / # (b) / – (pause)
(c) / Not used for this digit and
after (d) /
Any is OK (f).
5-8
Setting
External line connection number
setting 2 <First digit>
The numbers and codes which
can be registered are as fol-
lows.
0 - 9 / * (a) / # (b) / – (pause)
(c) / Not used for this digit and
after (d) /
Any is OK (f).
11
1-4
Setting
External line connection number
setting 2 <Second digit>
The numbers and codes which
can be registered are as fol-
lows.
0 - 9 / * (a) / # (b) / – (pause)
(c) / Not used for this digit and
after (d) /
Any is OK (f).
5-8
Setting
External line connection number
setting 2 <Third digit>
The numbers and codes which
can be registered are as fol-
lows.
0 - 9 / * (a) / # (b) / – (pause)
(c) / Not used for this digit and
after (d) /
Any is OK (f).
12
1-4
Setting
External line connection number
setting 2 <Fourth digit>
The numbers and codes which
can be registered are as fol-
lows.
0 - 9 / * (a) / # (b) / – (pause)
(c) / Not used for this digit and
after (d) /
Any is OK (f).
5
Not used
6 -7
Adjustment value
DT/BT detection level
MODEM fixed (400Hz)
0 0
420Hz - 600Hz
0 1
360Hz - 440Hz
1 0
245Hz - 650Hz
1 1
8
Setting
Busy tone detection
0: No
1: Yes
13
1-4
Adjustment value
Lower limit of call signal ON time
Not used
0 0 0 0
100ms
0 0 0 1
200ms
0 0 1 0
300ms
0 0 1 1
400ms
0 1 0 0
500ms
0 1 0 1
600ms
0 1 1 0
700ms
0 1 1 1
800ms
1 0 0 0
900ms
1 0 0 1
5-8
Adjustment value
Upper limit of call signal ON time
Setting range 1000ms to
4000ms
Two states input
SW
No.
Bit
No.
System set-
tings
Item
SW selection and function