– 21 –
MD-R2
8. TEST-PLAY mode
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the DELETE/CLEAR button. TEST-PLAY menu
[ T E S T _ P L A Y _ ]
Step 3
Press once the DISPLAY button.
ADRES setting (Target address initial value is indicated)
[ A D R E S _ 0 0 5 0 ]
Press once the MD PLAY button. During search the search output pin 11 is set to "H", and it is
returned to "L" when continuous playback is started.
Step 4
Continuous playback (pit section) (A C1 error indication)
[s
c
]
Continuous playback (groove section) (A C1 error indication)
[a
c
]
Step 5
Press once the DISPLAY/
(A ADIP error indication)
[a
a
]
CHARACTER button.
Step 6
Press once the MD STOP button. TEST-PLAY menu
[ T E S T _ P L A Y _ ]
Step No.
Setting Method
Remarks
Display
• If the MD STOP button is pressed while the TEST-PLAY menu is displayed, TEST mode STOP state is set.
• If the MD PLAY button is pressed while the TEST-PLAY menu is displayed, continuous playback is started from the current pickup position.
• Whenever the DELETE/CLEAR button is pressed in the address setting mode, the address changes as follows.
0 0 5 0
→
0 3 C 0
→
0 7 0 0
→
0 8 A 0
→
0 0 5 0
→
…………
• Whenever the DISPLAY/CHARACTER button is pressed in the address setting mode, the digit which is changed with -
/
+ changes
as follows.
0 0 5 0
→
0 0 5 0
→
0 0 5 0
→
0 0 5 0
→
…………
• The digit of address which has been specified with -
/
+ and DISPLAY/CHARACTER button in the address setting mode is set to +01H/
-01H.
* If the -
/
+ button is held down, the setting changes continuously with 100 ms cycle.
• If the TRACK EDIT button is pressed in the continuous playback mode, the number of jump lines changes as follows.
1 line
→
10 line
→
400 line
→
1 line
→
…………
* After the number of jump lines is indicated for one second, the address indication is restored.
[
T R _ J U M P ]
• If the -
/
+ button is pressed in the continuous playback mode, the specified number of lines is jumped in the FWD/REV
direction.
* If the -
/
+ button is held down, the setting changes with 100 ms cycle.
• Whenever the CD STOP button is pressed in the continuous playback mode, the indication changes as follows.
* Pit section Continuous playback (SUBQ address indi C1 error indication) remains.
* Groove section
Continuous playback (ADIP address indi C1 error indication) remains.
↓
Continuous playback (ADIP address indi ADIP error indication) remains.
↓
Continuous playback (ADIP address indi C1 error indication) remains.
↓
•
: Adress,
: Error late,
: Jump lines
………
9. TEST-REC mode
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the DELETE/CLEAR button
TEST-REC menu
[ T E S T _ R E C _ _ ]
two times.
Step 3
Press once the DISPLAY/
ADRES setting (indication of address initial value)
[ a 0 0 5 0 _ p w
]
CHARACTER button.
Step 4
Press once the MD PLAY button. During search the search output pin 11 is set to "H", and it is
(returned on "L" when continuous playback is started.A
C1 error indication) Continuous recording
[ a
p w
]
Step 5
Press once the MD STOP button. TEST-REC menu
[ T E S T _ R E C _ _ ]
Step No.
Setting Method
Remarks
Display
• If the MD STOP button is pressed while the TEST-PLAY menu is displayed, TEST mode STOP state is set.
• If the MD PLAY button is pressed while the TEST-REC menu is displayed, continuous record is started from the current pickup position.
• Whenever the DELETE/CLEAR button is pressed in the address setting mode, the address changes as follows.
0 0 5 0
→
0 3 C 0
→
0 7 0 0
→
0 8 A 0
→
0 0 5 0
→
…………
• Whenever the DISPLAY/CHARACTER button is pressed in the address setting mode, the digit which is changed with -
/
+ changes
as follows.
0 0 5 0
→
0 0 5 0
→
0 0 5 0
→
0 0 5 0
→
…………
• The digit of address which has been specified with -
/
+ and DISPLAY/CHARACTER button in the address setting mode is set to +01H/
-01H.
* If the -
/
+ button is held down, the setting changes continuously with 100 ms cycle.
• If the JOG button is pressed in TEST-REC mode and continuous record mode, the laser record power changes.
(Servo gain changes also according to the record power.)
•
: Adress,
: Laser power cord