MAX
-
PRO Operator Manual
Original Printed in English
FAULT & ALERT MANAGEMENT
4
-
2
Fault
Cause
Possible Solution (S)
Bag Failed To Open
The Bag Opened Sensor failed to
make as the Bag Open Fingers
were attempting to open the bag.
This fault is usually the result of a
problem with the Pressure Bar Pass
-
thru Adjustment or Bag Open Fin-
gers Adjustment. Also check that
the Sensor operates correctly.
Communication Fail
-
I/O Master
to Controller
Communications between Controller
and I/O master have been interrupt-
ed.
Verify cables are connected and
tightened properly.
Communication Fail
-
I/O Master
to I/O Node
Communications between I/O Mas-
ter and expected I/O node have
been interrupted
Verify cables are connected and
tightened properly.
Master I/O Communication Fail-
ure
Controller Disconnected
The controller is disconnected.
Connect the controller.
Palm Button Configuration Error
Machine is configured for a single
palm button, but second palm button
seen active.
Select Dual Palm Buttons in the
Factory Setup\Cycle Button.
Package Eject Guard Removed
Package Eject Sensor failed to read
guard.
1.
Mount the Package Eject
Guard.
2.
Adjust Sensor.