15” LCD Color Monitor Sharp LL-153A
35
5. Adjust the GREEN of color1 on factory window until CA210 indicator reached the value G=100
6. Adjust the BLUE of color1 on factory window until CA210 indicator reached the value B=100
7. Repeat above procedure (item 4,5) until CA210 R/G value meet the tolerance =100±5
8. Repeat above procedure (item 6) until CA210 B value meet the tolerance =126±5
C. Adjust 6500K color-temperature
1. Switch the CA210 to STD (with press “MODE” button)
2. Switch the MEM. Channel to Channel 3 (with up or down arrow on CA210)
3. The LCD-indicator on CA210 will show x = 313±15, y = 329±15,
4. Adjust the RED of color1 on factory window until CA210 indicator reached the value R=100
5. Adjust the GREEN of color1 on factory window until CA210 indicator reached the value G=100
6. Adjust the BLUE of color1 on factory window until CA210 indicator reached the value B=100
7. Repeat above procedure (item 4,5) until CA210 R/G value meet the tolerance =100±5
8. Repeat above procedure (item 6) until CA210 B value meet the tolerance =126±5
D. Adjust 5000K color-temperature
1. Switch the CA210 to 5000 (with press “MODE” button)
2. Switch the MEM. Channel to Channel 3 (with up or down arrow on CA210)
3. The LCD-indicator on CA210 will show x = 346±15, y = 359±15,
4. Adjust the RED of color1 on factory window until CA210 indicator reached the value R=100
5. Adjust the GREEN of color1 on factory window until CA210 indicator reached the value G=100
6. Adjust the BLUE of color1 on factory window until CA210 indicator reached the value B=100
7. Repeat above procedure (item 4,5) until CA210 R/G value meet the tolerance =100±5
8. Repeat above procedure (item 6) until CA210 B value meet the tolerance =126±5
E. Adjust 4000K color-temperature
1. Switch the CA210 to 4000 (with press “MODE” button)
2. Switch the MEM. Channel to Channel 3 (with up or down arrow on CA210)
3. The LCD-indicator on CA210 will show x = 282±15, y = 384±15,
4. Adjust the RED of color1 on factory window until CA210 indicator reached the value R=100
5. Adjust the GREEN of color1 on factory window until CA210 indicator reached the value G=100
6. Adjust the BLUE of color1 on factory window until CA210 indicator reached the value B=100
7. Repeat above procedure (item 4,5) until CA210 R/G value meet the tolerance =100±5
8. Repeat above procedure (item 6) until CA210 B value meet the tolerance =126±5
C. Turn the Power-button off to quit from factory mode.
Summary of Contents for LL-153A
Page 10: ...15 LCD Color Monitor Sharp LL 153A 10 4 4 Panel Specification 4 4 1 Display Characteristics ...
Page 12: ...15 LCD Color Monitor Sharp LL 153A 12 Back Light Unit ...
Page 24: ...15 LCD Color Monitor Sharp LL 153A 24 6 4 Audio Board ...
Page 25: ...15 LCD Color Monitor Sharp LL 153A 25 7 PCB Layout 7 1 Main Board ...
Page 26: ...15 LCD Color Monitor Sharp LL 153A 26 7 2 PWPC Board ...
Page 27: ...15 LCD Color Monitor Sharp LL 153A 27 7 3 Audio Board 715G1144 3 SH ...
Page 36: ...15 LCD Color Monitor Sharp LL 153A 36 10 Monitor Exploded View ...