15” LCD Color Monitor Sharp LL-153A
9
4.2 Factory Preset Display Modes
4.3 Power Supply
The power supply should be integrated to the monitor housing.
A/C Line voltage range
: 100 V ~ 240 V
A/C Line frequency range
: 50
±
3Hz, 60
±
3Hz
Current
: 1.5A max at 100V; 0.8A max at 240 V
Peak surge current
: < 55A peak at 240 VAC and cold starting
Leakage current
: < 3.5mA
Power line surge
: No advance effects (no loss of information or defect)
With a maximum of 1 half-wave missing per second
DC output Voltage
: 5VDC ± 5
%
; 12VDC± 5
%
Current
1.5Amp (5V)
;
2 Amp (12V)
Summary of Contents for LL-153A
Page 10: ...15 LCD Color Monitor Sharp LL 153A 10 4 4 Panel Specification 4 4 1 Display Characteristics ...
Page 12: ...15 LCD Color Monitor Sharp LL 153A 12 Back Light Unit ...
Page 24: ...15 LCD Color Monitor Sharp LL 153A 24 6 4 Audio Board ...
Page 25: ...15 LCD Color Monitor Sharp LL 153A 25 7 PCB Layout 7 1 Main Board ...
Page 26: ...15 LCD Color Monitor Sharp LL 153A 26 7 2 PWPC Board ...
Page 27: ...15 LCD Color Monitor Sharp LL 153A 27 7 3 Audio Board 715G1144 3 SH ...
Page 36: ...15 LCD Color Monitor Sharp LL 153A 36 10 Monitor Exploded View ...