LC-24LE170I
6 – 2
1. SIGNAL ADJUSTMENT
A. PICTURE ADJUSTMENT
Confirmation of signal from generator (setting to spec level)
PAL Composite signal
:
0.7Vp-p
±
0.02Vp-p (pedestal to white level)
33K Component signal (60Hz)
:
Y level
:
0.7Vp-p
±
0.02Vp-p (pedestal to white level)
Pb, Pr level
:
0.7Vp-p
:
0.7Vp-p
±
0.02Vp-Com
(1) Adjustment Mode
NO.
ITEM
CONDITION
PROCEDURE
i
Adjustment Mode
Press the test key at the test remote control
(2) Component 33K 60Hz Signal Adjustment (COMP-HD)
NO.
ITEM
CONDITION
PROCEDURE
i
Setting
[Signal]
COMP 33K 60Hz
(1080i)
100% Full-field Colour
Bar
[Terminal]
COMPONENT
INPUT
2
・
Feed the COMPONENT 33K 60Hz (1080i) 100% Full-field
Colour Bar signal(100% colour saturation) to COMPONENT
INPUT
2
ii
Auto Adjustment
Test Mode page 5
(COMP HD)
At the related page, move cursor to [COMP HD ADJ], press
ENTER.
[OK] appears when finished.
100% White
→
←
Black