2
KB-6524PS
KB-6524PK
KB-6524PW
C
RELAY TEST
4) Reconnect all leads removed from components during testing.
5) Re-install the covers.
6) Reconnect the power supply cord after the covers are installed.
7) Run the oven and check all functions.
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
B
KEY UNIT TEST
. Disconnect the power supply cord, and then remove outer case.
. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensure that these leads remain isolated from other components and oven chassis by using insulation
tape.
6. After that procedure, re-connect the power supply cord.
7. Remove the outer case and check voltage between Pin Nos. 5 and 7 of the 4 pin connector (CN-A)
on the power unit with an A.C. voltmeter.
The meter should indicate 20 volts, if not check oven circuit.
RY, RY2, RY3 and RY4 Relay Test
These relays are operated by D.C. voltage
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation.
DC. voltage indicated
Defective relay.
DC. voltage not indicated
Check diode which is connected to the relay coil. If diode is good,
control unit is defective.
RELAY SYMBOL
OPERATIONAL VOLTAGE
CONNECTED COMPONENTS
RY
Approx. 26V D.C.
Oven lamp / Common
RY2
Approx. 25V D.C.
Power transformer
RY3
Approx. 26V D.C.
Stirrer motor
RY4
Approx. 26V D.C.
Fan motor
RY5
Approx. 26V D.C.
Switching regurator for drawer motor
8. Disconnect the power supply cord, and then remove outer case.
9. Open the door and block it open.
0. Discharge high voltage capacitor.
. Reconnect all leads removed from components during testing.
2. Open the drawer and block it open.
3. Discharge high voltage capacitor.
4. If the display fails to clear when the STOP/CLEAR pad is depressed,
first verify the flat ribbon cable is making good contact, verify that
the door sensing switch (stop switch) operates properly; that is the
contacts are closed when the drawer is closed and open when the
drawer is open. If the door sensing switch (stop switch) is good,
disconnect the flat ribbon cable that connects the key unit to the
control unit and make sure the drawer sensing switch is closed
(either close the drawer or short the door sensing switch connecter).
Use the Key unit matrix indicated on the control panel schematic
and place a jumper wire between the pins that correspond to the
STOP/CLEAR pad making momentary contact. If the control unit
responds by clearing with a beep the key unit is faulty and must be
replaced. If the control unit does not respond, it is faulty and must be
replaced. If a specific pad does not respond, the above method may
be used (after clearing the control unit) to determine if the control
unit or key pad is at fault.
5. Reconnect all leads removed from components during testing.
6. Re-install the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.