SW30 No. 8 Quick on-line
It is selected whether auto dial call is activated in the memory input
mode when one document is completely read or when all pages are
completely read.
SW31 No. 1 ~ No. 4 Reserved
Set to "0".
SW31 No. 5 Reserved
Set to "1".
SW31 No. 6 Reserved
Set to "0".
SW31 No. 7 Reserved
Set to "1".
SW31 No. 8 Reserved
Set to "0".
SW32 No. 1 Print hold
When set to "1", the print hold function is enabled.
SW32 No. 2, No. 3 Reserved
Set to "0".
SW32 No. 4 Changeover of Print cassette
When the cassette selection priority is set to the upper priority or the
lower priority and paper in the cassette is exhausted, this function is
used to set changeover of the cassette of not.
SW32 No. 5 ~ No. 8 Selection of print cassette
Used to set the priority of selection of the recording paper cassettes.
(Auto selection/Upper priority/Lower priority)
SW33 No.1 No. 2 Heater mode
Used to set ON/OFF of the heater. Three settings are available: al-
ways ON, always OFF, and OFF timer. (Only when Off timer is se-
lected, SW34-SW37 settings are valid.)
SW33 No. 3 ~ No. 5 Density adjustment of print bias
The density of printing is set.
It can be also set in the print diagnosis mode.
SW33 No. 6, No. 7 Limit value of drum life
Used to set ON/OFF of the limit value of drum life.
SW33 No. 8 Reserved
Set to "0".
SW34 No. 1 ~ No. 4 Start time of heater OFF time (Upper digit of
hour)
Used to set the start time of the heater OFF timer. (Enter in 24-hour
system.)
SW34 No. 5 ~ No. 8 Start time of heater OFF time (Lower digit of
hour)
Used to set the start time of the heater OFF timer. (Enter in 24-hour
system.)
SW35 No. 1 ~ NO. 4 Start time of heater OFF time (Upper digit of
minute)
Used to set the start time of the heater OFF timer. (Enter in 24-hour
system.)
SW35 No. 5 ~ No. 8 Start time of heater OFF time (Lower digit of
hour)
Used to set the start time of the heater OFF timer. (Enter in 24-hour
system.)
SW36 No. 1 ~ No. 4 End time of heater OFF time (Upper digit of
hour)
Used to set the end time of the heater OFF timer. (Enter in 24-hour
system.)
SW36 No. 5 ~ No. 8 End time of heater OFF time (Lower digit of
hour)
Used to set the end time of the heater OFF timer. (Enter in 24-hour
system.)
SW37 No. 1 ~ No. 4 End time of heater OFF time (Upper digit of
minute)
Used to set the end time of the heater OFF timer. (Enter in 24-hour
system.)
SW37 No. 5 ~ No. 8 End time of heater OFF time (Lower digit of
minute)
Used to set the end time of the heater OFF timer. (Enter in 24-hour
system.)
SW38 No. 1 Reserved
Set to "0".
SW38 No. 2 Reserved
Set to "1".
SW38 No. 3 ~ No. 8 Reserved
Set to "0".
SW39 No. 1 Reserved
Set to "1".
SW39 No. 2 ~ No. 8 Reserved
Set to "0".
SW40 No. 1 Reserved
Set to "1".
SW40 No. 2 ~ No. 8 Reserved
Set to "0".
SW41 No. 1, No. 2 Reserved
Set to "0".
SW41 No. 3 Reserved
Set to "1".
SW41 No. 4, No. 5 Reserved
Set to "0".
SW41 No. 6 Reserved
Set to "1".
SW41 No. 7 Reserved
Set to "0".
SW41 No. 8 Reserved
Set to "1".
SW42 No. 1 Reserved
Set to "1".
SW42 No. 2 ~ No. 5 Reserved
Set to "0".
SW42 No. 6 Reserved
Set to "1".
SW42 No. 7 Reserved
Set to "0".
SW42 No. 8 Reserved
Set to "1".
SW43 No. 1 Reserved
Set to "1".
SW43 No. 2 ~ No. 5 Reserved
Set to "0".
SW43 No. 6 Reserved
Set to "1".
SW43 No. 7 Reserved
Set to "0".
SW43 No. 8 Reserved
Set to "1".
FO-4500H
2 – 33
Summary of Contents for FO-4500
Page 16: ...M E M O FO 4500H 1 14 ...
Page 129: ...Control PWB parts layout Top side 6 11 FO 4500H ...
Page 130: ...Control PWB parts layout Bottom side 6 12 FO 4500H ...
Page 133: ...TEL LIU PWB parts layout 6 15 FO 4500H ...
Page 134: ...6 16 FO 4500H ...
Page 136: ...Power supply PWB parts layout 6 18 FO 4500H ...
Page 141: ...M E M O 6 23 FO 4500H ...
Page 149: ...Scanner unit Fig 6 Optical adjustment tool Fig 7 Fig 8 FO 4500H 8 6 ...