CHAPTER 2. ADJUSTMENTS
[1] Adjustments
General
Since the following adjustments and settings are provided for this
model, make adjustments and/or setup as necessary.
1. Adjustments
Adjustments of output voltage (FACTORY ONLY)
1. Install the power supply unit in the machine.
2. Set the recording paper and document.
3. When the document is loaded, power is supplied to the output
lines. Confirm that outputs are within the limits below.
Output voltage settings
Output
Voltage limits
+5V
4.75V
∼
5.25V
V-REG
7.0V
∼
8.2V
+24V
23.3V
∼
24.7V
2. IC protectors replacement
ICPs (IC Protectors) are installed to protect the motor driver circuit.
ICPs protect various ICs and electronic circuits from an overcurrent
condition.
The location of ICPs are shown below:
(1) FU100 (ICP-S07) is installed in order to protect IC’s from an over-
current generated in the motor drive circuit. If FU100 is open,
replace it with a new one.
3. Settings
(1) Dial mode selector
DIAL mode (Soft Switch No. SWB4 DATA No. 3)
TEL/LIU
PWB
CONTROL
PWB
POWER
SUPPLY
PWB
CNPW
CNLIUA
CNLIU
CNLED
CNMT
CNTH
CNCCD
CNSP
CNCS
CNPN
(step 1) Select "OPTION SETTING".
DISPLAY:
DISPLAY:
DISPLAY: TONE SELECTED
KEY:
FUNCTION
4
KEY:
OPTION SETTING
PRESS
OR #
KEY:
DIAL MODE
1=TONE, 2=PULSE
KEY:
KEY:
DISPLAY:
(step 4) End, using the "STOP" key.
(step 3) Select, using "1" or "2".
(step 2) Select "DIAL MODE".
1
2
PULSE SELECTED
STOP
#
#
#
#
#
#
#
Cursor
When initially registering,
the mode shows 1=TONE.
When registering again, the
mode which was registered
formerly is shown.
#
Connector
No.
CNPW
Pin No.
1
MG
2
MG
3
MG
4
+24V
5
+24V
6
DG
7
+5V
8
DG
9
V-REG
CONTROL
PWB (TOP SIDE)
CNLIUA
FU100
UX-600MU/MC
FO-1660U/C
2 – 1
Summary of Contents for FO-1660
Page 15: ...M E M O UX 600MU MC FO 1660U C 1 13 ...
Page 72: ...Control PWB parts layout Top side 6 8 UX 600MU MC FO 1660U C ...
Page 73: ...Control PWB parts layout Bottom side 6 9 UX 600MU MC FO 1660U C ...
Page 75: ...TEL LIU PWB parts layout 6 11 UX 600MU MC FO 1660U C ...
Page 77: ...6 13 Power supply PWB parts layout UX 600MU MC FO 1660U C ...
Page 80: ...Operation panel PWB parts layout 6 16 UX 600MU MC FO 1660U C ...
Page 92: ...M E M O UX 600MU MC FO 1660U C 8 8 ...
Page 115: ......