PRO-60/70X5FD
5 – 9
*1 Details of P1.12 (NORMAL STANDBY CAUSE)
When TV set is powered off due to normal use or product specification, the last cause will be recorded.
The code, character string and description for the standby cause are below.
If you power off by remote, the cause will not be recorded.
*2 Details of P1.13 (ERROR STANDBY CAUSE)
When TV set is powered off due to any anomaly detection, the past 5 causes will be recorded.
You can confirm the time those causes occurred and character string in the adjustment process mode menu. (Page 28/29)
The time is accumulated total after TV set is powered on, and the value corresponds to “Center Acutime” in the adjustment process mode menu.
The code, character string and description for the standby cause are below.
If no error has occurred, the code is 0 and the character string is “NO RECORD”.
Monitor ERR STBY table
Outline: Communication/Power failure detected by the monitor microcomputer is stored on EEPROM, and the last 4 abnormal states can be
confirmed in the process mode A.
Location: Page 1 of the process mode A: MONITOR ERR CAUSE “0” if there is no error. It is cleared to 0 on the last page of the process mode A.
Code
Character string
Description
2
NO_OPERT
No operation off
3
NO_SIGNA
No signal off
6
SLEEP_TM
Off timer
8
OFF_232C
Command from RS232C
Code
Character string
Description
1A
E_MONITR
Monitor trouble detected
1B
E_CVICBT
Driver boot error
22
E_TCNERR
Software abnormality of LCD controller
48
E_MRESET
Failure of resetting menu settings (Initial Setup - Reset)
50
E_TCNF_S
T-CON FPGA status error
54
E_TCON_E
T-CON hung-up
Display (HEX) Display (DEC)
Error description
02
2
Start-up communication error 2
Initial communication from the main CPU is not received.
03
3
Start-up communication error 3
Only the initial communication is received.
04
4
Start-up communication error 4
Until panel information request reception
05
5
Start-up communication error 5
Until initialization completion reception
06
6
Start-up communication error 6
Until version notification transmission
07
7
Start-up communication error 7
Until start-up information notification transmission
08
8
Start-up communication error 8
Until start-up information response reception
09
9
Start-up communication error 9
Until time-out setting reception
0A
10
Communication error A
REQ time-out
0B
11
Communication error B
Restart time-out during the beginning of time acquisition start-up
0C
12
Communication error C
Ending sequence time-out
0D
13
Communication error D
Preset start-up time-out during completion
0E
14
Communication error E
download, start-up time-out
0F
15
Communication error F
Time acquisition time-out
11
17
Communication error H
Regular communication time-out
16
22
Panel-related error
Lamp failure
1A
26
Other error 2
Monitor temperature failure
1E
30
Power supply error 2
PS_ON (DET_13V) failure
1F
31
Power supply error 3
D_POW (DET_D3V3) failure
21
33
Power supply error 5
Panel power failure
23
35
Other error 3
Error standby request from the main CPU
Summary of Contents for Elite PRO-60X5FD