PRO-60/70X5FD
4 – 12
[4] Precautions for assembly
1. Points to be checked and precautions when servicing the unit
Mount the main PWB Ass’y on the backlight chassis and check that the EMI-prevention parts are not peeled and twisted from the access holes. (The
EMI-prevention parts, conductive nonwoven fabric gaskets, must be seen from the access holes.)
[Countermeasure]
Attach the conductive nonwoven fabric gaskets on the shielded case on the main PWB.
State where the main PWB and shielded case are assembled
PMLT-A678WJQZ x 2 pcs
PMLT-A679WJQZ
PSPAZC740WJZZ
Attach the conductive nonwoven fabric gasket on the RF terminal angle.
(PMLT-A680WJQZ)
Access hole
Access hole