– 21 –
MD-M3/M1
5. TEST-PLAY mode
Step 1
Test mode STOP state
The AUTO preliminary adjustment should have been completed.
[ t s m 1 3
e
]
Step 2
Press the NORMAL button.
TEST-PLAY menu
[ T E S T _ P L A Y _ ]
Step 3
Press once the DISPLAY button.
ADDRESS setting (Target address initial value is indicated)
[ A D R E S _ 0 0 5 0 ]
Press once the PLAY button.
Step 4
Continuous playback (pit section) (A C1 error indication)
[s
c
]
Continuous playback (groove section) (A C1 error indication)
[a
c
]
Step 5
Press once the DISPLAY button.
(A ADIP error indication)
[a
a
]
Continuous playback (groove section)
Step 6
Press once the STOP button.
TEST-PLAY menu
[ T E S T _ P L A Y _ ]
Step No.
Setting Method
6. TEST-REC mode
Step 1
Test mode STOP state
The AUTO preliminary adjustment should have been completed.
[ t s m 1 3
e
]
Step 2
Press twice the NORMAL button. TEST-REC menu
[ T E S T _ R E C _ _ ]
Step 3
Press once the DISPLAY button.
ADDRESS setting (indication of address initial value)
[ a 0 0 3 2 _ p w
]
Step 4
Press once the PLAY button.
While searching, set the search output to "H". To start continuous play,
[ a
p w
]
return it to "L".
Continuous recording
Step 5
Press once the STOP button.
TEST-REC menu
[ T E S T _ R E C _ _ ]
Step No.
Setting Method
Remarks
Display *
Remarks
Display *
(For confirmation of the playback ability at the named address.)
With recording mini disk (For confirmation of the playback ability at the named address.)
7. INNER mode
Step 1
Test mode STOP state
[ t s m 1 3
e
]
Step 2
Press the CD button.
INNER menu
[ _ _ I N N E R _ _ ]
Step 3
Press once the PLAY button.
INNER switch position measurement
[s
c
]
(SUBQ address and C1 error are also indicated.)
Step 4
Press once the STOP button.
INNER menu
[ _ _ I N N E R _ _ ]
Step No.
Setting Method
Remarks
Display *
•
: Address
4. EEPROM setting mode
Shown in page 23,24.
* Actual indicator character is shown on page 19 . ( See Table 19 )
• If the STOP button is pressed while the TEST-PLAY menu is displayed, TEST mode STOP state is set.
• If the PLAY button is pressed while the TEST-REC menu is displayed, continuous record is started from the current pickup position.
• Whenever the NORMAL button is pressed in the address setting mode, the address changes as follows.
0 0 5 0
→
0 3 C 0
→
0 7 0 0
→
0 8 A 0
→
0 0 5 0
→
…………
• Whenever the DISPLAY button is pressed in the address setting mode, the digit which is changed with / changes
as follows.
0 0 5 0
→
0 0 5 0
→
0 0 5 0
→
0 0 50
→
…………
• The digit of address which has been specified with / button in the address setting mode is set to +01H/-01H.(0~F)
* If the / button is held down, the setting changes continuously with 100 ms cycle.
• Be sure to remove since excessive raising results in breakage of the pickup.
▲
▲
▲
▲
▲ ▲
▲ ▲
▲
▲
▲
▲
▲ ▲
▲ ▲
▲
▲
▲
▲
▲ ▲
▲ ▲
* Actual indicator character is shown on page 19 . ( See Table 19 )
* Actual indicator character is shown on page 19 . ( See Table 19 )
• If the STOP button is pressed while the TEST-PLAY menu is displayed, TEST mode STOP state is set.
• If the PLAY button is pressed while the TEST-PLAY menu is displayed, continuous playback is started from the current pickup position.
• Whenever the NORMAL button is pressed in the address setting mode, the address changes as follows.
0 0 5 0
→
0 3 C 0
→
0 7 0 0
→
0 8 A 0
→
0 0 5 0
→
…………
• Whenever the DISPLAY button is pressed in the address setting mode, the digit which is changed with / changes
as follows.
0 0 5 0
→
0 0 5 0
→
0 0 5 0
→
0 0 5 0
→
…………
• The digit of address which has been specified with / button in the address setting mode is set to +01H/-01H.(0~F)
* If the / button is held down, the setting changes continuously with 100 ms cycle.
▲
▲
▲
▲
▲ ▲
▲ ▲
▲
▲
▲
▲
▲ ▲
▲ ▲
▲
▲
▲
▲
▲ ▲
▲ ▲