– 19 –
MD-E9000H
KEY
Segment
5. KEY test (Function: Key and last display)
Function: Key and last display
Power off after lighting up the odd number grids, even numbered grids and lighting up FL pipe segment which corresponded
to KEY until TEST MODE is cancelled.
TEST MODE
LIGHT UP ODD
NUMBERED GRID
1.0 sec TIMER
(WAIT)
1.0 sec TIMER
(WAIT)
LIGHT OFF
KEY INPUT
LIGHT UP EVEN
NUMBERED GRID
KEY INPUT =
"POWER"?
It does the display which was
allocated for the key while each
KEY INPUT was pressed.
NO
YES
POWER OFF.
TEST CANCEL.
Notice: 1. REMOCON input during test mode is invalid.
2. Volume "0"
Segment light up when pressed correspond key
MD EJECT
ALL LIGHT UP
AUX
OVER
SP
TUNER
ST &
LP2
LP2
CD EJECT
TOC
LP4
LP4
VOLUME UP
RDS
NORMAL EDIT
GROUP
VOLUME DOWN
PTY
HIGH EDIT
HIGH
CD STOP
TP &
MD REC
REC
CD PLAY
TA
MEMORY
MEMORY
MD STOP
DISC
DISPLAY
RANDOM
MD PLAY
TRACK &
X-BASS
BASS
SKIP UP
EON &
EQUALIZER
T-EDIT
SKIP DOWN
TI & SLEEP
KEY