R-350F
20
1. CARRY OUT 3D CHECKS.
2. Disconnect the wire leads from panel components.
3. Remove the one (1) screw holding the control panel
assembly to the oven flange.
4. Slide the control panel assembly upward and remove it.
5. Now, individual components can be removed.
NOTE: 1. Before attaching a new key unit, wipe off
remaining adhesive on the control panel frame
surfaces completely with a soft cloth soaked in
alcohol.
2. When attaching the key unit to the control panel
frame, adjust the upper edge and right edge of
the key unit to the correct position of control
panel frame.
3. Stick the key unit firmly to the control panel
frame by rubbing with soft cloth not to scratch.
TURNTABLE MOTOR REMOVAL
1. Disconnect oven from power supply.
2. Remove turntable and turntable support from oven
cavity.
3. Lay the oven on it's backside. Remove the turntable
motor cover by snipping off the material in four corner.
4. Where the corners have been snipped off bend corner
areas flat. No sharp edge must be evident after removal
of the turntable motor cover.
5. Disconnect wire leads from turntable motor.
(See "Positive lock connector removal")
6. Remove two (2) screws holding turntable motor to oven
cavity.
7. Now the turntable motor is free.
8. After replacement use the one (1) screw to fit the
turntable motor cover.
NOTE: The one (1) screw to fit the turntable motor cover
should be XHTSD40P08RV0.
COOLING FAN MOTOR REMOVAL
1. CARRY OUT 3D CHECKS.
2. Disconnect the wire leads from the fan motor.
3. Remove the magnetron and the chassis support from
the waveguide, referring to "MAGNETRON REMOVAL".
4. Release the snap of the main wire harness from the fan
duct.
5. Remove one (1) screw holding the fan duct assembly
to the oven cavity.
6. Release the main wire harness from the hole of the fan
duct.
7. Release the fan duct from the waveguide flange.
8. Release the fan duct assembly from the oven cavity.
9. Remove the fan blade from the fan motor shaft according
the following procedure.
1) Hold the edge of the rotor of the fan motor by using a
pair of grove joint pliers.
CAUTION:
*
Make sure that any pieces do not enter the gap
between the rotor and the stator of the fan motor
because the rotor is easily shaven by pliers and
metal pieces may be produced.
*
Do not touch the pliers to the coil of the fan motor
because the coil may be cut or injured.
*
Do not disfigure the bracket by touching with the
pliers.
2) Remove the fan blade from the shaft of the fan motor
by pulling and rotating the fan blade with your hand.
3) Now, the fan blade will be free.
CAUTION:
*
Do not reuse the removed fan blade because the
hole (for shaft) may be larger than normal.
10.Remove the two (2) screws holding the fan motor to the
fan duct.
11.Now, the fan motor is free.
INSTALLATION
1. Install the fan motor to the fan duct with the two (2)
screws.
2. Install the fan blade to the fan motor shaft according the
following procedure.
1) Hold the center of the bracket which supports the shaft
of the fan motor on the flat table.
2) Apply the screw lock tight into the hole (for shaft) of the
fan blade.
3) Install the fan blade to the shaft of fan motor by pushing
the fan blade with a small, light weight, ball peen
hammer or rubber mallet.
CAUTION:
*
Do not hit the fan blade strongly when installed
because the bracket may be disfigured.
*
Make sure that the fan blade rotates smooth after
installation.
*
Make sure that the axis of the shaft is not slanted.
3. Catch three holes of fan duct on three tabs of the
waveguide flange.
4. Install the fan duct assembly to the oven cavity with the
one (1) screw.
Figure C-2. CPU unit
Printed wiring board
of CPU unit
Liquid Crystal
Display (LCD)
Ribbon cable
CONTROL PANEL ASSEMBLY REMOVAL
CPU UNIT
NOTE: Handle the CPU unit carefully so that the ribbon
cable does not come off. Because the ribbon cable
is sticked on the LCD and the printed wiring board
only by heated paste.
Summary of Contents for Carousel R-350F
Page 2: ...R 350F 36 ...