17
R-1405
R-1406
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
Resistance between;
BLU (1)
AND
YLW (4) =
0
Ω
(Shorted)
BLK (2)
AND
YLW (4) = 60
Ω
BLU (1)
AND
BLK (2) = 60
Ω
RED(5)
AND
BLU (1) = 162
Ω
RED(5)
AND
BLK (2) = 102
Ω
YLW(4)
AND
RED (5) = 162
Ω
6-PIN CONNECTOR
OF HOOD FAN MOTOR
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
BLU BLK
YLW RED
1
2
4
5
60
Ω
102
Ω
HOOD FAN
CAPACITOR
YLW
RED
BLU
BLK
1
2
4
5
SUB
60 Hz
120 v
MAIN