AYXP7FR
1 – 3
3. AY-XP12FR – AE-X12FR
NOTE: The condition of star”
✩
” marked item are ‘ISO5151’ : 1994(E), contition T1.
MODEL
INDOOR UNIT
OUTDOOR UNIT
ITEMS
AY-XP12FR
AE-X12FR
Cooling capacity(Min. > Max.)
kW
3.5 (0.9 - 3.8)
Heating capacity(Min. > Max.)
kW
4.0 (0.9 - 6.0)
Moisture removal(at cooling)
Liters/h
Electrical data
Phase
Single
Rated frequency
Hz
50
Rated voltage
V
230
Rated current
✩
(Min - Max.)
Cool
A
5.0 (1.1 - 8.2)
Heat
A
4.8 (1.0 - 8.0)
Rated input
✩
(Min - Max.)
Cool
W
1090 (210 - 1300)
Heat
W
1030 (180 - 1900)
Power factor
✩
Cool
%
95
Heat
%
93
Compressor
Type
Hermetically sealed rotary type
Model
5RS102XBE01
Oil charge
320cc (RB68A or Freol Alpha 68M)
Refrigerant system
Evaporator
Louver Fin and Grooved tube type
Condenser
Corrugate Fin and Grooved tube type
Control
Expansion valve
Refrigerant (R410A)
1030g
De-lce system
Micro computer controled reversed systems
Noise level
(at cooling)
High
dB(A)
40
48
Low
dB(A)
–
–
Soft
dB(A)
28
–
Fan system
Drive
Direct drive
Air flow quantity
(at cooling)
High
m3/min.
9.8
26.7
Low
m3/min.
8.5
–
Soft
m3/min.
6.9
–
Fan
Cross flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
3/8", 1/4"
Drain piping mm
O.D
φ
18
Others
Safety device
Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters
Polypropylene net (Washable)
Net dimensions
Width
mm
790
730
Height
mm
278
540
Depth
mm
198
250
Net weight
kg
10
37