AYXP7FR
1 – 1
AYXP7FR
Service Manual
CHAPTER 1.
SPECIFICATION
[1] SPECIFICATION
1. AY-XP7FR – AE-X7FR
MODEL
INDOOR UNIT
OUTDOOR UNIT
ITEMS
AY-XP7FR
AE-X7FR
Cooling capacity(Min. > Max.)
kW
2.1 (0.9 - 2.5)
Heating capacity(Min. > Max.)
kW
2.4 (0.9 - 3.4)
Moisture removal(at cooling)
Liters/h
Electrical data
Phase
Single
Rated frequency
Hz
50
Rated voltage
V
230
Rated current
✩
(Min - Max.)
Cool
A
2.5 (1.0 - 4.1)
Heat
A
2.4 (0.9 - 4.5)
Rated input
✩
(Min - Max.)
Cool
W
530 (200 - 760)
Heat
W
510 (160 - 1100)
Power factor
✩
Cool
%
92
Heat
%
92
Compressor
Type
Hermetically sealed rotary type
Model
DA89X1F-23F
Oil charge
370cc (VG74)
Refrigerant system
Evaporator
Louver Fin and Grooved tube type
Condenser
Corrugate Fin and Grooved tube type
Control
Expansion valve
Refrigerant (R410A)
830g
De-lce system
Micro computer controled reversed systems
Noise level
(at cooling)
High
dB(A)
37
45
Low
dB(A)
–
–
Soft
dB(A)
28
–
Fan system
Drive
Direct drive
Air flow quantity
(at cooling)
High
m3/min.
8.0
23.2
Low
m3/min.
6.8
–
Soft
m3/min.
5.5
–
Fan
Cross flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
3/8", 1/4"
Drain piping mm
O.D
φ
18
Others
Safety device
Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters
Polypropylene net (Washable)
Net dimensions
Width
mm
790
730
Height
mm
278
540
Depth
mm
198
250
Net weight
kg
10