AR-FX12 SIMULATIONS, FAX SOFTWARE SWITCH 6-47
70 1-4 Pause time setup
(between dialing)
Used to set the pause time of every pause input in dialing. The set range is 0 -
15 by binary input of N into "1sec x N" (1sec - 15sec). When 0 is selected, it is
set to the default (2sec).
0
2sec
Initial setup
0
1
0
5
Detection of line current
when dialing
Used to set whether dialing is made or not after detection of the line current
when connecting the line in automatic dialing.
When it is set to YES and the line current is not detected, dialing is not made.
1
NO
6
Dial tone detection
Used to set whether the dial tone is detected or not in automatic dialing.
When it is set to YES and the dial tone is not detected, dialing is not made.
0
NO
7
Dial tone monitoring
time
Used to set the judgment time for detection of dial tone.
0
5sec
8
FAX calling CNG
detection
Used to set whether CNG from the other party is detected or not when FAX
calling.
When it is set to YES and CNG is detected, the line is judged as busy.
0
Not
detected
71 1,2 Frequency range setup
for detection of DT/BT
Used to set the frequency range for detection of dial tone and busy tone.
When dial tone or busy tone is erroneously detected, change the setting.
( ): Theoretically proper area
1
245Hz ~
650Hz
1
3
Busy tone detection
Used to set whether the busy tone signal is detected or not during automatic
dialing or ringing of pseudo-call of an external telephone.
0
Detected
4,5 Busy tone detection
cycle
Used to set the number of pulses for judgment of busy tone signal detection.
0
2 pulses
0
6,7 DT/BT detection level
Used to set the minimum detection level for judgment of dial tone and busy tone
detection. If a signal level is lower than this setup, it is ignored.
0
-43dB
0
8
None-detection time of
busy tone OFF
Used to set none-detection time of busy tone OFF.
Change the setup when busy tone ON section is abnormal due to noises.
0
100ms
72 1,2 Lower limit of busy tone
detection time
(ON time)
Used to set the lower limit of detection time (ON time) of busy tone signal
frequency. To count a busy tone signal as 1 pulse, it must be detected for more
than the set time.
For CTR21, 150ms.
0
250ms
0
SW
No.
Bit
No.
Item
Switch selection and function
USA
Initial value
Key
operator
1: NO
0: YES
1: YES
0: NO
1: 17sec
0: 5sec
1: CNG detection YES
0: CNG detection NO
Bit No.
4
5
245Hz ~ 650Hz
(North America, CTR21)
1
1
360Hz ~ 440Hz (Australia, German)
1
0
420Hz ~ 680Hz
0
1
Modem fixed
(Japan, UK, France, Sweden)
0
0
1: Busy tone is not detected. 0: Busy tone is detected.
Bit No.
4
5
2Pulse
0
0
4Pulse
0
1
6Pulse
1
0
10Pulse
1
1
Bit No.
6
7
-43dB
0
0
-35dB
0
1
-33dB
1
0
-30dB
1
1
1: 300ms
0: 100ms
Bit No.
1
2
250ms
0
0
150ms
0
1
450ms
1
0
350ms
1
1
[06]SIMULATIONS
・
FAXSOFTWARESWITCH.fm 47
ページ
2004年10月26日 火曜日 午後3時44分