
AR-5618S FLASH ROM VERSION UP PROCEDURE 12-5
4. AR-5618N/5620N/5623N download
procedures
1) Install the driver for the AR-5618N/5620N/5623N to a PC used for
firmware update (hereinafter described as the download PC).
2) Prepare a cross cable and connect it to the download PC.
3) Disconnect the LAN cable (which is being used by the user) from the
machine, and connect the cross cable to the machine.
4) Set the IP address of the machine.
Execute “setup.exe” in the driver CD for the AR-5618N/5620N/
5623N, and select [Set the OP Address].
5) Press [Yes].
6) Check to confirm that [Ethernet Address] of the installed NIC PWB is
displayed, and select [Ethernet Address] and press [Next >].
7) Enter the IP address, and press [Next >].
If an error screen is not displayed, the IP address setting is
completed.
8) Set the IP address of the download PC to the fixed IP address (the
same segment set to the machine in the procedure 4) ).
9) Boot the SC-SCAN.
10) Execute SIM49-01 on the machine side.
Select [SHARP AR-DOWNLOAD], and press [Connect].
11) Boot the maintenance tool to execute downloading.
(The same operations as the AR-5620N are executed.)
12) Reset the IP address of the machine and the download PC to the
original states.
AR-5618N