AR-122E/152E/153E/157E MAINTENANCE 11 - 1
[11] MAINTENANCE
1. Maintenance table
: Check (Clean, adjust, or replace when required.)
: Clean
: Replace
: Adjust
✩
: Lubricate
2. Maintenance display system
Section
Parts
25K
50K
75K
100K
125K
Remark
Developing
Developer
DV blade
DV side seal (F/R)
Process peripheral
Drum
Toner
Life
8K
Remaining quantity
NEAR EMPTY
About 10%
EMPTY
LED
ON
Flash
Machine
Operation allowed
Stop
Developer
Life
25K
LED
ON at 25K of the developer count.
Machine
Selection is available between Not Stop and Stop by Service Simulation (SIM 26-37) Setup.
(If Stop is selected, the LED will flash and stop at 25K.)
∗
Default: Not Stop
∗
Clear: SIM 24-06
Maintenance
LED
Selection is available among 18K, 13K, 9K, 6K, 3K, and free (no lighting) with SIM 21-1.
∗
Default: free
∗
Clear: SIM 20-1
Machine
Not stop.