AR-122E/152E/153E/157E SIMULATION, TROUBLE CODES 10 - 9
43
01
Fusing temperature setup (Normal copy)
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
04
Fusing temperature setup 2
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
05
Fusing temperature setup in duplex copy
In duplex copy, this setup value is added to the fusing temperature of single copy. When this simulation is executed, the current setup
of the code number is displayed. Enter the code number and press the PRINT switch to enable the setup.
09
Setup of fusing control of postcard size paper
Main
code
Sub
code
Content
Code number
Set temperature (°C)
0
175
1
180
2
185
3
190
4
195 (* Default)
5
200
Code number
Set temperature (°C)
0
155
1
160
2
165
3
170 (* Default)
4
175
5
180
Code number
Temperature shift (°C)
0
±0°C * Default
1
– 8°C
2
– 6°C
3
– 4°C
4
– 2°C
5
±0°C
6
+2°C
7
+4°C
8
+6°C
9
+8°C
The default for Japan model is “1.”
Code number
Setup
0
Cancel * Default
1
Setup