LC-70LE632U/633U
4 – 2
Table 1. Concrete flashing pattern
*2: They depend on the system. Power supply error is defined from product to product.
*3: For details, refer to ERROR STANDBY CAUSE on the adjustment process screen.
*4: If the boot section is abnormal, there is no flashing (flashing impossible).
3. New method
Item
Detail display
Cause
Slow flashing
Fast flashing
Inverter/Lamp system failure
Flashes once
Flashes once
Lamp error
Power PWB
failure
(Power failure, etc.)
Flashes twice
Flash once
Power supply error 2 (*2) AC_DET error
Flash twice
Power supply error 2 (*2) UR+13V error
Flash 3 times
Power supply error 2 (*2) D+3.3V error
Flash 5 times
Panel power supply error
Main PWB
failure
(Communication
failure, etc.)
Flashes 3 times
Flashes once
Initial communication error
Flashes twice
Start-up confirmation communication error
Flashes 3 times
Regular communication error
Flashes 5 times
Other communication error
Others
Flashes 4 times
Flashes once
Temperature error
Flashes twice
Sync error
Flashes 3 times
Notification from the main microcomputer (*3)
VerUP executing
Flashes smoothly
None
Version upgrading
VerUP succeeded
Flashes in a staircase pattern
None
Version upgrade succeeded
VerUP failed
None
Flashes continuously
Version upgrade failed
ROM data failure
None
Flashes continuously
Start-up after failing version upgrade (*4)
Center icon
Center icon
Center icon
Flashing during Verup
Flashing when completing Verup
1600ms
300ms
100ms
500ms
500ms
1000ms
400ms
400ms
1600ms
1000ms
1000ms
1000ms