LC-70LE632U/633U
3 – 13
9. White balance adjustment
9.1. White balance adjustment (For details about the adjustment procedure, refer to “Kameyama Model Integrated Monitor
WB Adjustment Specification V1.92”.)
Adjustment
point
Adjustment conditions
Adjustment procedure
1
Setting
1) Set the unit to the following conditions.
AV MODE: [DYNAMIC]
Backlight: +16
Active Backlight: OFF
Aging Time: Min. 60 minutes
2) Connect the unit with the white balance adjustment jig.
2
Automatic
adjustment exe-
cution
[Command]
Process mode
KRSW0001
KKT10037
Setting
KY0F0000
0SDS0001
SBSL0016
Multi-point adjustment mode
MSET0001
Point 6
LEV60232
MG6G****
MG6B****
MG6R****
Point 5
LEV50194
MG5G****
MG5B****
MG5R****
Point 4
LEV40151
MG4G****
MG4B****
MG4R****
Point 3
LEV30107
MG3G****
MG3B****
MG3R****
Point 2
LEV20072
MG2G****
MG2B****
MG2R****
Point 1
LEV10045
MG1G****
MG1B****
MG1R****
Writing
MSET0003
[Adjustment procedure]
1) Send the “adjustment process” code using the remote control.
2) Set the point 6 to the specified gradation, specify the strongest color as the fixed
color, and adjust the RGB so that it becomes the standard value through negative
adjustment.
3) Set the point 5 to the specified gradation, set the G correction value (776 x G value of
point 6/928) (fractions rounded off) and adjust the RB so that it becomes the stan-
dard value.
4) Set the point 4 to the specified gradation, set the G correction value (604 x G value of
point 6/928) (fractions rounded off) and adjust the RB so that it becomes the standard
value.
5) Set the point 3 to the specified gradation, set the G correction value (428 x G value of
point 6/928) (fractions rounded off) and adjust the RB so that it becomes the standard
value.
6) Set the point 2 to the specified gradation, set the G correction value (288 x G value of
point 6/928) (fractions rounded off) and adjust the RB so that it becomes the standard
value.
7) Set the point 1 to the specified gradation, set the G correction value (180 x G value of
point 6/928) (fractions rounded off) and adjust the RB so that it becomes the standard
value.
8) Write the adjustment value by the MSET0003 command and turn off the AC power.
* RGB initial value of point 6: Set gradation 928
* RGB initial value of points 1 to 5: G correction value of each point
(At each point, make adjustment so that the remainder of the RGB adjustment value/
4 is equal.)
[Adjustment value]
* According to the “Standard settings” submitted by the Technical Department
[LC70LE632U] teaching set