LC-60/70EQ10U,SQ10U/15U/17U,TQ15U,UQ17U
5 – 16
Point 2
LEV20048
MG2R0192
[Adjustment standard value]
Measuring instrument: [TOPCON SR-UL2] Technical measuring instrument.
MG2G0192
Level
Reference value
Adjustment spec
Inspection spec
MG2B0192
Point 7
928
X=0.3127
±
0.0010
±
0.0020
MG2Y0192
1G2G****
y=0.329
1G2B****
1G2R****
Point 6
784
X=0.3127
±
0.0015
±
0.0030
1G2Y****
y=0.329
Point 1
Point 5
624
X=0.3127
±
0.0020
±
0.0040
LEV10020
y=0.329
MG1G0000
Point 4
432
X=0.3127
±
0.0030
±
0.0060
MG1B0000
y=0.329
MG1R0000
Point 3
304
X=0.3127
±
0.0035
±
0.0070
MG1Y0000
y=0.329
1G1G****
Point 2
192
X=0.3127
±
0.0040
±
0.0080
1G1B****
y=0.329
1G1R****
1G1Y****
The MAX brightness mea-
sured after adjustment
CHGM1255
Remarks
Setting conditions for inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Active Backlight: OFF
Aging Time: Min. 60 minutes
Writing
MSET0030
Brightness specification after adjustment.
LC-60/70UQ17U:Min 368cd/m2
LC-80UQ17U:Min 328cd/m2
Adjustment
point
Adjustment conditions
Adjustment procedure
Summary of Contents for Aquos LC-60SQ10U
Page 46: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 2 36 MEMO ...
Page 89: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U ...
Page 101: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 2 2 ...
Page 102: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 2 3 ...
Page 103: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 2 4 ...
Page 104: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 2 5 ...
Page 105: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 2 6 ...
Page 218: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 7 4 MEMO ...