LC-60/70EQ10U,SQ10U/15U/17U,TQ15U,UQ17U
5 – 14
[Adjustment standard value]
Measuring instrument: [TOPCON SR-UL2] Technical measuring instrument.
Level
Reference value
Adjustment spec
Inspection spec
Point 7
928
X=0.272
±
0.0010
±
0.0020
y=0.277
Point 6
784
X=0.2755
±
0.0015
±
0.0030
y=0.2720
Point 5
624
X=0.2755
±
0.0020
±
0.0040
y=0.2720
Point 4
432
X=0.2755
±
0.0030
±
0.0060
y=0.2720
Point 3
304
X=0.2755
±
0.0035
±
0.0070
y=0.2720
Point 2
192
X=0.2755
±
0.0040
±
0.0080
y=0.2720
Remarks
Setting conditions for inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Active Backlight: OFF
Aging Time: Min. 60 minutes
Brightness specification after adjustment.
LC-60SQ10U,15U,17U/EQ10U/TQ15U:Min 240cd/m2
LC-70SQ10U,15U,17U/EQ10U/TQ15U:Min 240cd/m2
Adjustment
point
Adjustment conditions
Adjustment procedure