LC-60/70LE600U
6 – 11
1) Center Icon illumination
LED flashing timing chart for error notification.
Error type
Center Icon illumination operation (1 cycle)
Pins are microprocessor pins.
Lamp error
Flashes once: Fast
[Center Icon illumination]
H: On
L: Off
Judged by the ERR_PNL port. Confirmed after 10 consecutive
detections at 500 ms intervals (detected only when the backlight is
on).
[Released]
• Execute AC_ON with [INPUT] and [VOL-DOWN] on the unit
down. Then execute the function of “L ERR RESET” in the
adjustment process mode menu.
• Continuous illumination for 15 minutes.
NOTE: After five detection counts, the lamp cannot be activated.
Temperature error
Flashes 4 times
[Center Icon illumination]
H: On
L: Off
Judged by monitoring temperature with the temperature sensor.
When the panel temperature is 63
°
C or more, caution is dis-
played. If the panel temperature is 65
°
C or more, error standby is
activated.
[Released]
Reduce the value of TEMP CAUTION (temperature caution
threshold) and TEMP SHUTDOWN (temperature protection
threshold) in the adjustment process mode menu.
Error Type
Panel power error
Flash 2 times
H: On
L: Off
Judged panel power supply by the DET_POW_port.
Conformed after 2 consecutive detections at 16mS intervals.
400ms
1600ms
Summary of Contents for Aquos LC-60LE600U
Page 6: ...LC 60 70LE600U 1 1 LC 60LE600U Service Manual CHAPTER 1 SPECIFICATIONS 1 SPECIFICATIONS ...
Page 7: ...LC 60 70LE600U 2 1 LC 60LE600U Service Manual CHAPTER 2 OPERATION MANUAL 1 PARTS NAMES ...
Page 8: ...LC 60 70LE600U 2 2 2 OPERATION MANUAL ...
Page 9: ...LC 60 70LE600U 2 3 ...
Page 10: ...LC 60 70LE600U 2 4 ...
Page 11: ...LC 60 70LE600U 2 5 ...
Page 12: ...LC 60 70LE600U 3 1 LC 60LE600U Service Manual CHAPTER 3 DIMENSIONS 1 DIMENSIONS ...
Page 57: ...LC 60 70LE600U ...
Page 67: ...LC 60 70LE600U ...