LC-60/70LE600U
5 – 4
6. Writing the microprocessor software
6.1. Writing the main microprocessor software and monitor microprocessor software
(Main PWB: QPWBXF905WJZZ)
7. Signal adjustment
7.1. LCD section adjustment [LCD module adjustment]
7.2. Image adjustment
7.2.1 Device check
Before adjustment, check that the adjustment jig and signal source are set for Sharp LCD US.
Signal generator level adjustment check (Adjust to the standard value level.)
7.2.2 Process mode
Adjustment item
Adjustment conditions
Adjustment procedure
1
Writing the software
Checker process
Checking the file version
Checking the USB memory
1) Connect the USB memory to J501 (TL514-517).
2) Set the PWB correctly and apply the specified voltage to it; then write the soft-
ware on it.
3) After confirming the completion of the writing operation, turn off the power.
4) File name
JAS_DTV_US_P102_Vx.xxF_AP.BIN
(x.xxx software version)
CAUTION: When the USB memory is not inserted or reading error occurs, nothing
is written.
Adjustment item
Adjustment conditions
Adjustment procedure
1
Opposite bias adjustment
(LCD module adjustment
item)
Adjustment in the center
position of the panel
1) Enter the process mode using the process adjustment remote control.
2) Select [VCOM ADJ] using the Channel
/
keys on the remote control.
3) Press the Enter key to check that the pattern for adjustment is displayed.
4) Make adjustment so that the flicker located in the center of the screen is mini-
mized using the /- keys on the remote control.
5) If the optimum condition is obtained in step 4, press the Enter key to turn off the
pattern.
CAUTION: * Make adjustment with no ANT signal (since the brightness is changed
by the active backlight).
[Adjustment position]
•
15K component signal:
Y level:
0.714Vp-p
±
0.02Vp-p (Pedestal to white)
PB/PR level:
0.7Vp-p
±
0.02Vp-p
•
33K component signal:
Y level:
0.7Vp-p
±
0.02Vp-p (Pedestal to white)
PB/PR level:
0.7Vp-p
±
0.02Vp-p
•
Analog RGB:
RGB level:
0.7Vp-p
±
0.02Vp-p (Pedestal to white)
Adjustment point
Adjustment conditions
Adjustment procedure
Process mode
Enter the process adjustment mode using the process adjustment remote control.
1/2
1/2
1/2
1/2
Summary of Contents for Aquos LC-60LE600U
Page 6: ...LC 60 70LE600U 1 1 LC 60LE600U Service Manual CHAPTER 1 SPECIFICATIONS 1 SPECIFICATIONS ...
Page 7: ...LC 60 70LE600U 2 1 LC 60LE600U Service Manual CHAPTER 2 OPERATION MANUAL 1 PARTS NAMES ...
Page 8: ...LC 60 70LE600U 2 2 2 OPERATION MANUAL ...
Page 9: ...LC 60 70LE600U 2 3 ...
Page 10: ...LC 60 70LE600U 2 4 ...
Page 11: ...LC 60 70LE600U 2 5 ...
Page 12: ...LC 60 70LE600U 3 1 LC 60LE600U Service Manual CHAPTER 3 DIMENSIONS 1 DIMENSIONS ...
Page 57: ...LC 60 70LE600U ...
Page 67: ...LC 60 70LE600U ...