LC-42/46/52D85X
5 – 9
8. STANDBY CAUSE FUNCTIONS
This model is equipped with a STANDBY CAUSE FUNCTIONS which stores the cause of why the unit is turned off and displays it on adjustment pro-
cess mode.
1. NORMAL STANDBY CAUSE
ERROR CODE here indicates cause of standby in normal operation or Function of the Unit.
No display when the unit is turned off with R/C.
Only the latest cause is indicated.
2. ERROR STANDBY CAUSE
ERROR CODE here indicates cause of Error in the unit.
It also indicates accumulated operating times of the unit.
The last five histories are displayed.
1)-5) five histories 1) is the latest.
When there is no error, error code is ‘0’ and no characters appear.
3. MONITOR ERROR CAUSE
When the monitor micom detects an error, ERROR CODE is displayed.
The number of flashing Power LED and OPC LED indicates location of error detected.
This number stores the latest four contents of the error. ‘0’ is displayed when no error.
•
NORMAL STANDBY CAUSE
•
ERROR STANDBY CAUSE
•
MONITOR ERROR CAUSE
Display Code
Indication
Description
2
NO_OPERT
in the cause of “no operation off”
3
NO_SIGNA
in the cause of “no signal off”
6
SLEEP_TM
in the cause of “SLEEP timer”
8
OFF_232C
in the cause of command by RS-232C
Display Code
Indication
Description
17
E_AVCTMP
in the cause of abnormal temperature
Display
Error Reason
Power (RED) LED
Blink Times
OPC LED
Blink Times
01
Initial Communication Error 1
Not used
02
Initial Communication Error 2
Cannot receive initial communication from main CPU
3 times
1 time
03
Initial Communication Error 3
Receive initial communication only
3 times
2 times
04
Initial Communication Error 4
To the communication setting reception
3 times
2 times
05
Initial Communication Error 5
To the initialization completion reception
3 times
2 times
06
Initial Communication Error 6
To the notice of version reception
3 times
2 times
07
Initial Communication Error 7
To the notice of start information reception
3 times
2 times
08
Initial Communication Error 8
To the start information answer reception
3 times
2 times
09
Initial Communication Error 9
To the time-out setting reception
3 times
2 times
0A
Communication Error A
Request Time-out
3 times
Off
0B
Communication Error B
Restart Time-out
3 times
4 times
0C
Communication Error C
End sequence Time-out
Off
Off
0D
Communication Error D
Reserve start Time-out when End seqence
Off
Off
0E
Communication Error E
Download Start Time-out
3 times
Off
0F
Communication Error F
Get Time Start Time-out
Off
Off
10
Communication Error G
Not used
11
Communication Error H
Watchdog Time-out
3 times
3 times
12
Communication Error I
Not used
13
Communication Error J
Not used
14
Communication Error K
Not used
15
Power (RED) LED Blink 0
Not used
16
Power (RED) LED Blink 1
Lamp Error
1 time
Off
17
Power (RED) LED Blink 2
AC_DET Error
2 times
1 time
18
Power (RED) LED Blink 3
Not used
19
Power (RED) LED Blink 4
Not used
1A
Power (RED) LED Blink 5
Monitor Temperature Error
5 times
Off
1B
Power (RED) LED Blink 6
Not used
1C
Power (RED) LED Blink 7
Not used
1D
Power supply Error 1
PS_ON(DET_10V) Error
2 times
3 times
1E
Power supply Error 2
Not used