37
LC-32GD4U
LC-37GD4U
4. Lamp error detection
4-1. Feature description
This liquid-crystal color TV incorporates a lamp error detection feature (lamp error detection) that
automatically turns OFF the power for safety under abnormal lamp or lamp circuit conditions.
If anything is wrong with the lamp or lamp circuit or when the lamp error detection feature is activated for
some reason, the following will result.
1
The power of TV main body is turned OFF about six seconds after it is turned ON. (The power LED on
the front of the TV turns red from green and keeps blinking in red (ON for 240ms and OFF for 1sec)).
2
If occurs five times consecutively, it becomes impossible to turn ON the power. (The power LED keeps
blinking in red (ON for 240ms and OFF for 1sec)).
4-2. Measures
1) Checking with lamp error detection OFF
While the POWER switch is off, hold down the "CH (
Ù
)" and "VOL (+)" keys and then turn the POWER
switch on. The display will run in the "Display process mode" ("<K>" will appear).
If there is a problem with a lamp or a lamp circuit, the lamp will go out. (The power LED is green.)
Then, you can check the operation to see if the lamp and lamp circuit are abnormal.
2) Resetting the lamp error count
After you have finished checking whether the lamp and lamp circuit are abnormal, reset the lamp error
count. If a lamp error is detected five consecutive times, the power cannot be turned on.
Therefore, move to the [L ERR RESET] line, the 5th line on the first page of the "Display process mode",
using the Cursor UP/DOWN key. Then, reset the [L ERR RESET] value using the Cursor RIGHT/LEFT
key. In this case, press the Cursor UP/DOWN key to reset it to "0".
Table of contents of adjustment process mode Page 0
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
S
E
R
V
I
C
E
I
32/37 G
D
2
U
→
1
G
R
A
Y
L
E
V
E
L
1
0
0
2
C
O
M
B
I
A
S
2
0
0
Values specific to each display
3
V
L
S
B
I
A
S
0
4
1
4
L
E
R
R
R
E
S
E
T
5
Reset to "0 "
5
L
C
D
6
P
A
T
T
E
R
N
7
M
O
T
O
R
A
N
D
F
A
N
8
O
T
H
E
R
9
V
E
R
M
2
0
3
After resetting to "0", perform an operational check to ensure that the lamp error detection feature is not activated.
Summary of Contents for Aquos LC-32GD4U
Page 15: ...15 LC 32GD4U LC 37GD4U Dimensions LC 32GD4U ...
Page 16: ...16 LC 32GD4U LC 37GD4U Dimensions LC 37GD4U ...
Page 38: ...38 LC 32GD4U LC 37GD4U 6 List of adjustment process modes Display Examples 32 37 2 ...
Page 39: ...39 LC 32GD4U LC 37GD4U 32 37 2 ...
Page 55: ...55 LC 32GD4U LC 37GD4U M E M O ...
Page 159: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËAV Unit 1 5 D3 D4 ...
Page 160: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËAV Unit 2 5 D5 D6 ...
Page 161: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËAV Unit 3 5 D7 D8 ...
Page 162: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËAV Unit 4 5 D9 D10 ...
Page 163: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËAV Unit 5 5 D11 D12 ...
Page 164: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËKEY Unit D13 D14 ...
Page 165: ...6 5 4 3 2 1 A B C D E F G H 6 5 4 3 2 1 A B C D E F G H ËR C LED Unit ËFRONT Unit D15 D16 ...
Page 166: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËDVI Unit 1 2 D17 D18 ...
Page 167: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËDVI Unit 2 2 D19 D20 ...
Page 215: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËPOWER Unit D115 D116 ...
Page 222: ...6 5 4 3 2 1 A B C D E F G H ËEXT SP TERMINAL Unit D129 ...