26
LC-26GA5E
LC-32GA5E
LC-26GA6E/LC-26BV6E
LC-32GA6E/LC-32BV6E
LC-37GA6E
COUNTERS
SW FROM MAINS
XXXXX
SW ON TIMES
XXXXX
SW OFF TIMES
XXXXX
WORKING HOURS
XXXXX
FAC. DATE DDMY
XXXX
GA6 VX.XX
ExpX
PxW Exp X.X LCD VXX
Use the up / down arrows to select a term in the
menu.
Confi rm the selection with
OK.
Press END button to return to the previous menu.
CPLD:
NOT OPERATIVE
STOP BUS:
Stop IC communication.
EXT 2 RGB
: Enable or disable the RGB entry over EXT2 connector.
FLASH UPGRADE:
Select ON to update to software update. (See page 23)
RAM TEST:
Check the RAM memory. It is working correctly when “OFF” appear on the screen. If any number appear,
the memory is not working correctly.
Counters Menu
To see information about TV.
OTHERS
CPLD
MENU
KEYS
STOP
BUS
VPS_8/30
EXT 2 RGB
OFF
FLASH UPGRADE
OFF
RAM
TEST
OFF
COUNTERS
GA6 VX.XX
ExpX
PxW Exp X.X LCD VXX
SW FROM MAINS:
Number of times that turn on the TV by the main switch.
SW ON TIMES:
Number of times that switch on the TV by the R/C.
SW OFF TIMES:
Number of times that switch on the TV by the R/C.
WORKING HOURS:
Number of hours that is working the TV.
FAC. DATE DDMY:
TV manufacture date (day, month, year).
Press END button to return to the previous menu.
KEYS Menu
Control menu of good operation of the top panel control keys.
If, when a key of the panel is pressed, the value who appears is within the parameters that appear in this menu, the
operation of this key is correct. High values near FF means, no key pressed.
Press END button to return to the previous menu.
MENU KEYS
ADC1:
F5
ADC2:
F5
GA6 VX.XX
ExpX
PxW Exp X.X LCD VXX
www.ma163.com 电子技术资料网