AL-2040CS SIMULATION, TROUBLE CODES 10 - 9
43
09
Fusing control setting for postcard-size paper
When this simulation is executed, the currently set code number is displayed.
Enter the code number and press START key to save the setting.
11
Fusing temperature setting for postcard-size paper
When this simulation is executed, the current set value is displayed.
Press UP/UP key to select the setting, and press START key to write into the EPROM. The display returns to the sub code
input standby mode.
14
Fusing start temperature setting
The fusing temperature when starting printing (first – second sheet) is set.
When this simulation is executed, the currently set code number is displayed.
When the code number is entered with UP/UP key and the START key is pressed, setting is changed over.
∗
The cassette feed and the manual feed are controlled similarly.
15
Postcard size paper fusing control cycle sync setting
When this simulation is executed, the currently set code number is displayed.
Change the setting with UP/UP key, and press START key to write the setting to the EEPROM. (Setting range: 0 – 20, default:
0)
∗
When set to "0," the setting is canceled and the fusing temperature control and the paper pass timing are not synchronized.
The conventional control (control same as the other paper) is performed.
∗
When set to "1" – "20," the postcard pass is synchronized with the fusing temperature control cycle, providing stable fusing
performance. However, CPM is reduced.
∗
When set to "1" – "20," if "Set value x 0.5°C + Temperature control level," the fusing heater lamp is turned OFF.
Main
code
Sub
code
Content
Code number
Temperature shift (°C)
0
Cancel * Default
1
Setting
Code number
Temperature shift (°C)
0
160
1
165
2
170
3
175
4
180
5
185
6
190
7
195 * Default
8
200
Code number
Set temperature (°C)
0
160
1
165
2
170
3
175
4
180
5
185
6
190
7
195 (* Default)
8
200
Mode
Lamp ON
Main cassette paper feed & 2nd cassette paper feed
AE mode lamp
Manual paper feed
TEXT mode lamp
Code number
Sync setting
Fusing heater lamp OFF timing temperature
0
Cancel
– (* Default)
1
Setting
+0.5°C
:
:
6
+3.0°C
:
:
20
+10.0°C
Summary of Contents for AL-2030