DG
B
1-43
S H A R P
Date Revised : Aug.7, 2001
Date Issued : Jun.1, 1998
MATERIAL SAFETY DATA SHEET (1/4)
MSDS No. F-30831
1. PRODUCT AND COMPANY IDENTIFICATION
Product Name
: AL-100TD / DM-150TD / AL-110TD / AL-110DC (Black Developer)
Supplier Identification
: Sharp Corporation
22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
Local suppliers are listed below. Please contact the nearest supplier for additional information.
(Country)
(Name and Telephone Number)
U.S.A.
Sharp Electronics Corporation
Telephone number for information :1-800-237-4277
Emergency telephone number
:1-800-255-3924
Canada
Sharp Electronics of Canada Ltd.
Telephone number for information : 905-890-2100
Emergency telephone number
:1-800-255-3924
United
Sharp Electronics (U.K.) Ltd.
Kingdom
Telephone number for information : 01922-474013
Australia
Sharp Corporation of Australia PTY. Ltd.
Telephone number for information : 1300-12-50-22
Germany
Sharp Electronics (Europe) GMBH
Telephone number for information : 40-2376-2737
2. COMPOSITION/INFORMATION ON INGREDIENTS
Substance [ ]
Preparation [ X ]
Ingredient
CAS No.
Proportion OSHA PEL ACGIH TLV
MAK-TWA NOHSC-TWA
Iron powder
7439-89-6
85-95%
Not listed
Not listed
Not listed
Not listed
Styrene-Acrylate 29497-13-1
1-5%
Not listed
Not listed
Not listed
Not listed
copolymer
Styrene
9002-52-6
1-5%
Not listed
Not listed
Not listed
Not listed
homopolymer
Carbon black
1332-86-4
< 1%
3.5g/m
3
3.5g/m
3
Not listed
3.5g/m
3
3. HAZARDOUS IDENTIFICATION
Most Important Hazards and Effects of the Products
Human Health Effects : There are no anticipated carcinogenic effects from exposur based on animal tests
performed using toner. When used as intented according to instructions, studies
do not indicate any symptons fibrosis will occur.
Environmental Effects : No data are available.
Specific hazards :
None
4. FIRST-AID-MEASURES
Route(s) of Entry :
Inhalation?
Skin?
Ingestion?
No
No
Possible but very unusual.
Inhalation :
Remove to fresh air. If symptons occur, consult medical personnel.
Skin Contact : Wash with soapand water for 15 minutes or until particle is removed.
If irritation does occur, consult medical personnel.
Eye Contact :
Flush eyes immediately with water for 15 minutes. If irritation does occur, consult
medical personnel.
Ingestion :
Rinse with water and drink several glasses of water. If irritation or discomfort does
occur, consult medical personnel.
Summary of Contents for AL-1043