26
AH-S22AW2
AH-S25AW2
6. After closing the open panel, open the vertical
adjustment louver and pull out the bottom of the front
panel toward you.
Lifting the front panel, strongly pull the top toward you.
Making the front panel parallel to the main body,
strongly pull it toward you for removal.
To install the front panel, place the bottom of the front
panel under the open vertical adjustment louver, and
press in the front panel, parallel to the cabinet. When
pressing it in, take care to prevent the top of the blow-
out port of the drain pan from being caught by the front
panel.
9. Remove the control box cover.
Holding its bottom, pull and disengage the upper hook
toward the bottom.
7. Remove the unit-to-unit wiring from the terminal board.
(Loosen the screw with the screwdriver, and pull out
the wiring.)
8. Remove one fastening screw from the control box
cover.
10.Remove the ground wire. (One screw)
Note: During reassembly, take care for the direction
of the lead wire.
11.Remove the protect cover for the dew.
Note: During reassembly, verify that the dew on
the pipe is led to the drain pan.